Corsair TX750 V2 750 W Review 4

Corsair TX750 V2 750 W Review

Value & Conclusion »

Ripple Measurements

In the following table you will find the ripple levels that we measured on the main rails of TX750 V2. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V & 3.3V).

Ripple Measurements
Test12 V5 V3.3 VPass/Fail
20% Load7.8 mV4.2 mV4.0 mVPass
40% Load11.6 mV4.8 mV5.2 mVPass
50% Load14.2 mV5.0 mV5.4 mVPass
60% Load17.6 mV5.2 mV5.8 mVPass
80% Load22.4 mV6.0 mV6.2 mVPass
100% Load28.2 mV7.0 mV7.4 mVPass
Crossload 113.2 mV5.8 mV5.2 mVPass
Crossload 227.4 mV7.2 mV7.4 mVPass

Ripple and noise suppression is excellent. The +12V rail did not exceed 30 mV ripple and the minor rails stayed bellow 8 mV in all tests! Simply amazing! If they keep constructing PSUs like this one then in the end ripple measurements will become colorless.

Ripple at Full Load

In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals to 0.01V) as standard but sometimes we are forced to use 0.02 V/Div, meaning that the fluctuations will look smaller but actually this wont be the case.



Ripple at Crossload 2

As above the order of images is +12V, 5V and 3.3V.