Ripple Measurements
You will see the ripple levels we measured on the rails of the G-550 in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Seasonic SSR-550RM-V2 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 6.3 mV | 5.0 mV | 9.8 mV | 6.5 mV | Pass |
---|
20% Load | 7.9 mV | 5.3 mV | 10.5 mV | 7.1 mV | Pass |
---|
30% Load | 9.6 mV | 5.5 mV | 10.6 mV | 8.7 mV | Pass |
---|
40% Load | 12.4 mV | 5.9 mV | 11.1 mV | 8.8 mV | Pass |
---|
50% Load | 13.8 mV | 5.7 mV | 11.3 mV | 9.3 mV | Pass |
---|
60% Load | 16.9 mV | 11.2 mV | 11.4 mV | 10.4 mV | Pass |
---|
70% Load | 19.5 mV | 13.2 mV | 12.2 mV | 10.9 mV | Pass |
---|
80% Load | 22.0 mV | 14.5 mV | 12.6 mV | 11.6 mV | Pass |
---|
90% Load | 25.3 mV | 15.5 mV | 13.2 mV | 12.5 mV | Pass |
---|
100% Load | 28.6 mV | 18.0 mV | 13.5 mV | 13.5 mV | Pass |
---|
110% Load | 34.8 mV | 19.4 mV | 12.9 mV | 15.1 mV | Pass |
---|
Crossload 1 | 8.4 mV | 6.6 mV | 11.9 mV | 12.2 mV | Pass |
---|
Crossload 2 | 27.5 mV | 16.1 mV | 13.7 mV | 12.4 mV | Pass |
---|
Ripple suppression was great on all rails, which we have come to expect from a Seasonic product. On the +12V rail, the G-550 managed to stay below one-fourth of the limit, and the other rails performed equally well.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2