Radiator Thermal Testing Specifications
Introduction
Rather than continue to copy and past the same testing
specifications and clutter other pages, I've decided to detail out my
method for testing radiators here.
But before I do that, I'd like to thank the following sponsors in my testing:
With all of this, I'm able to get a pretty good and accurate
understanding of how you can estimate performance depending on the fan
used and generate some decent information. Below are some more
details and links of the radiator testing equipment used:
Radiator
Testing Specifications:
- Thermal Temperature and Fan RPM Monitoring - CrystalFontz CFA-633 32 Channels of temperature, 4 channels of
fan RPM, Logging Capability in CSV format exportable to excel, .5C absolute
accuracy. Used to log 14 individual temperature sensors and one fan RPM sensor
to log results at 1 second intervals. Here is a small data example of what just one run looks like which is
logged in the below chart, thankfully the Crystalfontz does most of the work for
me.
- Test Bench Sensors Deployed -
- 6 each air inlet
sensors, two for each 120mm fan section (2 sensors are used for
every fan section of radiator, 2 for a 120, 4 for a 240, etc.)
- 4 each air outlet sensors, 1 for each 120mm fan section (1-2 sensors are used for every fan section of radiator).
- 1 water inlet sensor
- 1 water outlet sensor
- Custom Test Bench - Custom built
120mm x 4 radiator test bench with permanently mounted sensors to improve
consistency and minimize setup time.
- Flow rate - King Instruments
7520 Series 0-5GPM, 250mm scale - Accuracy 2% of Full Scale. Flow rate is
controlled via 3/4" brass gate valve to precisely 1.5GPM. Flow rate effects are
generally minimal in radiators so I have selected 1.5GPM as a good average flow
rate point.
- Water - I used regular filtered tap water for testing purposes.
- Warm-up - Each fan configuration
is allowed to reach temperature for 30-45 minutes until equilibrium is
met. This is determined by recording and logging of temperatures for at
least 1 hour and only averaging the results that are found after
equilibrium is obtained.
- Fans and RPMs tested:
- Logging of Temperatures - Each temperature sensor and fan rpm channel is
logged for 30 minutes to both average out any temperature fluctuations and also
to ensure the system has stabilized and heat loads/fan RPMs remained
constant during the testing period. If temperatures did not fluctuate or an
error occurred, the test was thrown out. Over a 30 minute period data for all
14 temperature sensors and fan header are recorded every second producing a data
matrix of 1,800 entries over each channel.
- Air Inlet Temperature Data - Each test averages the 8 inlet channels (6 in
the case of a triple radiator), and then average over the testing period of
1,800 results. So Air In can be the average of up to 8 x 1800 = 14,400 data
points collected.
- Water Outlet Temperature Data - Water outlet data is also captured by the
same Dallas sensor with an average of 1,800 data points collected.
Typical Test Logging for Each Fan Scenario and
Heat Load
- Water - I used regular filtered tap water for testing purposes.
- Warm-up - Each fan configuration is allowed to reach
temperature for 30 minutes minimum prior to recording and logging of
temperatures. I found that it takes around 15minutes to reach
equilibrium when deltas are in the 5C range, and up to 45minutes for
deltas of 15C.
- Open Environment Testing - I also wanted to note,
that I am
not insulating the coolant lines, my flow rate meter, or my
reservoir, so the c/w values I generate are for the complete system.
I am using about 6' of 1/2" ID by 3/4" tubing, a 14" King
Instruments flow meter, a 3/4" brass gate valve, and at tall 4"
diameter by 24" tall reservoir which do loose some heat during testing.
Initially I had thought about insulating my system, but the more I've
thought about it, a regular water cooling system also looses heat
through tubing and reservoirs, so I think it's an acceptable heat loss
that is similar to normal water cooling systems. I also have and will
continue to test every radiator exactly the same, so they all have
these same heat loss advantages through the test system. The one
variable I can't fix is the ambient temperature changes, and there is
some differences in thermal properties of air as it changes. I
think they are probably small enough to keep my results within 5% or
so, but it's still something I don't have control over where an
environmental chamber would be ideal.