TFC XChanger 480ER Radiator Review
Introduction
Welcome to my review of The Feser Company (TFC) X-Changer 480ER radiator.
This radiator would be of the "double thickness quad" sized
radiator specifically designed for those that must have the absolute
highest radiator performance with silent fan systems. First I
would like to give special thanks to
Martin from The Feser Company for providing me with a sample to test.
The Feser Company is based out of Germany and coming out with
many high quality products for your water cooling needs. Check out
their website for the latest developments in water cooling technology.
With this review I plan to cover radiator characteristics,
hydraulic restriction, and thermal performance with a wide range of
fans. I'll follow my typical engineering/technical flavor and
keep the commentary to the point about my results and observations. In the end, I hope to provide
you with some tools to help you design your water cooling system with
this radiator. While I'll touch on some comparisons, the ultimate
goal is to help you better understand how heat load and fan selection
affects the performance of this radiator as well as hydraulic
restriction.
The TFC XChanger 480ER houses 4x 120mm fans per side to maximize performance in a single radiator unit.
Radiator Characteristics
Here are some characteristics I
noted in my review:
- Double Thickness/Dual Row provides increased efficiency in transferring of heat from the fins to the air.
- Dual pass flow - Water flows down one half of the radiator and back up for a second pass before exiting.
- Separate top plenum chambers prevents any possibility of internal leaks and
ensures 100% of the water flows through the radiator tubes.
- 12 tubes per row (24 total) - Oversized dimensions maximize frontal surface area
- Copper louvered fins - Copper material and louvers for maximum air heat transfer.
- G 1/4 Threads - Water cooling standard for maximum barb compatibility
- Dimensions- 523mm x 126mm x 60mm (L x W x H) - For details see this drawing from TFC.
- Silent Fan Optimized Fin Density - 214 folds per the 19 inch frontal length or 11.3 FPI - Optimized for lower speed fans.
- Built in shroud of approximately 1/4" depth - Minimizes fan hub dead air space affect.
- Bleed screw in bottom plenum chamber for air removal assistance if needed (Inverted barb orientation).
- 3 year warranty is standard - Quality is guaranteed!
Standard G1/4 barb threading will accept a wide array of barbs.
Also note the individual plenum chambers to prevent any possibility of flow bypass.
Here you see the TFC signature logos and bottom bleed screw to assist
with air removal if the radiator is mounted vertically with barbs on
bottom.
TFC also sells their products at local retail shops, so they employ a very nicely presented set of documentation and packaging.
Including a 3 YEAR WARRANTY!
Radiator Package Contents
The radiator is a thick premium performance style, open finned radiator
optimized for lower speed fans. Here are some characteristics I
noted:
- TFC XChanger 480ER comes air sealed in a thick plastic
bag which ensure moisture protection and prevents damage from small
objects.
- 4 Noise absorbing silicone pads for fan vibration absorption and sealing.
- M3 screws for 120mm fans and case mounting
- Documentation - Introduction, Features, Warranty, Serial Number, and Instructions.
- 50ml TFC Feser Base
- 2X Compression Fittings
The packaging contents was very
complete, I was particularly happy to see the radiator comes in a very
thick heat sealed bag protecting the radiator. I have seen
several forum threads from other radiator manufacturers where the user
opens a box to a damaged radiator due to packaging screws damaging the
fragile radiator fins. You'll
be happy to know this thick air tight sealing bag will not only prevent
water/air corrosion damage it will also ensures there is no chance
mounting
screws can find their way into the radiator fins and cause damage.
Kudos to TFC for taking extra care in packaging their product, very nice attention to detail!
Hydraulics and Pressure Drop Testing
The
most scientific way to determine a blocks hydraulic resistance is to test
pressure drop. Pressure drop is a measurement of pressure loss across a radiator
that varies with flow rate. This is basically a measurement of energy loss, and
directly influences how much flow rate you will have.
Equipment:
- Dwyer
Digital Manometer 477 Mark V - Accuracy .5% of Full Scale. Range 0-20.00 PSI range, Resolution .01 PSI
- King
Instruments 7520 Series 0-5GPM, 250mm scale - Accuracy 2% of Full Scale.
Range 0-5GPM, Resolution .1 GPM (can be interpolated to .02GPM)
- Water Source - Household water pressure - 50PSI at >5GPM - Because flow
rate readings are instantaneous, household tap water and water pressure are a
good and powerful source for pressure drop testing.
Pressure drop testing shows the 480 is extremely low in restriction, several times lower than an average CPU block.
This pressure drop testing was ran with the above TFC 1/2" ID X 3/4" Feser compression barbs.
TFC XChanger 480ER is KING of Quad radiators for the lowest restriction, very nice!!
TFC X-Changer is a
"Double Thickness" or "Dual Row" design, you get twice the number of
tubes (24 over two rows vs 12 over a single row) that water can flow through. This is extremely beneficial
in reducing pressure drop and a large part of why double thickness
radiators generally have lower restriction.
While benefits to increase flow rates are generally small beyond 1.0GPM
for most water blocks, a lower restriction component like the radiator
does provide you a fair
amount of flexibility. This lower
restriction does provide either more pumping power for you to use in
adding more components (more blocks or radiators) without impeding
flow too much, or it offers you higher flow rates for higher
efficiency of your CPU block. In addition these higher flow rates
generally mean your system will bleed air faster when initially setup.
Also keep in mind my thermal testing is all based around a 1.5GPM fixed
flow rate, so because this radiator is very low in restriction is very
possible you could attain higher than 1.5GPM and slightly better
thermal efficiency and performance than I've captured here.
Thermal Testing Specifications
Welcome to
my thermal testing of this radiator, but first I would like to give special
thanks to Linus from NCIX.com for providing me with two sets of fans for
testing. They provided me with both the Yate Loon D12SL12 slow speed 47cfm 120x25mm fans, as well as
this Scythe Ultra Kaze DFS123812-3000 high speed 136cfm 120x38mm
fans. Both fans present great value and a strong variety of cfm coverage for
different setups.
For a more complete understanding of fan performance vs noise, I would recommend Vapor's fan testing on a radiator, Round 2, Round 3.
Comparing actual CFM on a radiator vs noise is the ideal means to
compare fans. In addition pay particular attention to his
comments about undervolting noise, because decibels by themselves don't
tell you if it's a pleasant smooth or clicking type noise that is also
very important.
I'm taking the "Scientific" approach to testing the radiator, and doing
so by using and measuring an external heat source and apply two heat
loads across 5 different fan scenarios. Using the two heat loads
allows me to check my work, average out error, and use higher heat
loads
than needed for measuring larger differences. In addition this
testing allows me to
use more accurate thermal sensors than those available in a processor.
In the
end I am then able to calculate a linear c/w
ratio trendline for each fan type. This is a very handy ratio for
estimating, (c/w
stands for degrees Celcius above ambient per watt of heat).
Having the c/w ratio allows you to estimate the water
temperature for any heat
load....ahhh we have science and a TOOL!. Furthermore, because
I'm testing over a large range of fan scenarios, I can then plot the
fan RPM relative to the c/w values generated. While RPM from two
fan types is not a direct performance relation (Pressure is equally as
important), it surprisingly still creates a decent fan power trend-line
curve. Regardless, the real advantage to
doing this RPM vs C/W chart is gaining a much bigger perspective on how
the radiator's
performance changes over the use of different fan types. In
general you will see as radiators are more dense and thicker, they will
have a larger variance in performance from the lower speed/pressure fan
types to higher speed fan types. You will also see that radiators
that are more open finned generaly perform better with lower speed fans
than those with much more dense fin structure.
In addition to the "Scientific" approach, I'm also going a bit extreme
on the sensors I'm deploying to measure all of this. Because this
c/w ratio is a measurement of "Air" into the radiator, you have to
seriously consider how much variability there is in air temperatures
throughout a room and even across different points on the radiator. Air is actually
considered an insulator, so if you don't measure air at several
locations and average them, the amount of error is much higher than you
would
expect. Some of the measurements may only be a few degrees at
lower heat loads, so it's almost a must to measure with higher accuracy
thermometers, use several to measure several points, and log
temperatures over a long period of time to average out fluctuations. With that, I've decided
I would
employ at least two digital air in sensors per 120mm section of radiator with
a
.2C mean error, and of course logging temperatures over at least
30minutes after an appropriate 30minute warm up period. All of
this helps make up for the fact that I do not have an environmental
chamber with controlled and consistent air temperatures.
With all of this, I'm able to get a pretty good and accurate
understanding of how you can estimate performance depending on the fan
used and generate some good information for you to use. Below are some more
details and links of the radiator testing equipment used:
Radiator
Testing Specifications:
- Thermal Temperature and Fan RPM Monitoring - CrystalFontz CFA-633 32 Channels of temperature, 4 channels of
fan RPM, Logging Capability in CSV format exportable to excel, .5C absolute
accuracy. Used to log 14 individual temperature sensors and one fan RPM sensor
to log results at 1 second intervals. Here is a small data example of what just one run looks like which is
logged in the below chart, thankfully the Crystalfontz does most of the work for
me.
- Thermal Sensors - Dallas DS18B20 Digital one-wire sensors. .5C absolute
accuracy overall with a .2C mean error between 20-30C.
- Heat Source - Two modified 300watt aquarium heaters.
I've taken the thermostat out of two heaters, and run two tests.
One with just one heater and one with the other. Both of
these heaters reside in my 4" custom reservoir and wattage is
determined by a Kill-a-watt that the heaters are plugged into.
- Test Bench Sensors Deployed -
- 8 each air inlet sensors, two for each 120mm fan section
- 4 each air outlet sensors, 1 for each 120mm fan section
- 1 water inlet sensor
- 1 water outlet sensor
- Custom Test Bench - Custom built
120mm x 4 radiator test bench with permanently mounted sensors to improve
consistency and minimize setup time.
- Flow rate - King Instruments
7520 Series 0-5GPM, 250mm scale - Accuracy 2% of Full Scale. Flow rate is
controlled via 3/4" brass gate valve to precisely 1.5GPM. Flow rate effects are
generally minimal in radiators so I have selected 1.5GPM as a good average flow
rate point although there will be some small benefit if higher than 1.5GPM flow rates are obtained, it's generally fairly small.
- Water - I used regular filtered tap water for testing purposes.
- Warm-up -
Each fan configuration is allowed to reach temperature for at least 30
minutes prior to recording and logging of temperatures. Typically
it takes about 20minutes for the high speed fans to reach equilibrium
and 30minutes for the low speed fans.
- Fans:
- Logging of Temperatures - Each temperature sensor and fan rpm channel is
logged for at least 30 minutes to both average out any temperature fluctuations and also
to ensure the system has stabilized and heat loads/fan RPMs remained
constant during the testing period. If temperatures did not fluctuate or an
error occurred, the test was thrown out. Over a 30 minute period data for all
14 temperature sensors and fan header are recorded every second producing a data
matrix of 1,800 entries over each channel.
- Air Inlet Temperature Data - Each test averages the 8 inlet channels (6 in
the case of a triple radiator), and then average over the testing period of
1,800 results. So Air In can be the average of up to 8 x 1800 = 14,400 data
points collected.
- Water Outlet Temperature Data - Water outlet data is also captured by the
same Dallas sensor with an average of 1,800 data points collected.
Typical Test Logging for Each Fan Scenario and
Heat Load
- Fan RPM - Also recorded and monitored with the Crystalfontz. Fan RPM is
carefully adjusted using a Sunbean fan speed controller to be the following:
- 12V Full Speed - Each fan is first adjusted to 12.00V +- .05V for the full
speed test runs
- RPM - Subsequent fan scenarios are voltage adjusted to match RPMs as
specified with 10RPM.
- Open Environment Testing - I also wanted to note,
that I am
not insulating the coolant lines, my flow rate meter, or my
reservoir, so the c/w values I generate are for the complete system.
I am using about 6' of 1/2" ID by 3/4" tubing, a 14" King
Instruments flow meter, a 3/4" brass gate valve, and at tall 4"
diameter by 24" tall reservoir which do loose some heat during testing.
Initially I had thought about insulating my system, but the more I've
thought about it, a regular water cooling system also looses heat
through tubing and reservoirs, so I think it's an acceptable heat loss
that is similar to normal water cooling systems. I also have and will
continue to test every radiator exactly the same, so they all have
these same heat loss advantages through the test system. The one
variable I can't fix is the ambient temperature changes, and there is
some differences in thermal properties of air as it changes. I
think they are probably small enough to keep my results within 5% or
so, but it's still something I don't have control over where an
environmental chamber would be ideal.
So there you have it, my attempt at making my testing as accurate as I
can without the luxury of an environmental chamber to maintain constant
temperatures.
Thermal Testing
For testing consistency purposes I always mount my fans with
preinstalled 1/8" foam sealed to the edges. This is not necessary as
the provided TFC silicone gaskets provided are exceptionally well made,
but in essence of testing radiators equally, I followed suit and tested
as shown below with the fan snugly sealed to the radiator without
anything but the foam gasket sealing any air gaps. Note that I
also always test with the fans in "PULL" condition such that air is
sucked through the radiator like a vacuum.
These were my tabular results of the 10 hour long tests without any shroud.
Note that under ultra slow speed fans it manages over 85%
air capacity efficiency, very nice!!
Now to take those results and plot them on a Heat Load (Watts) vs. Air In - Water Out (C) chart for estimating temperatures:
And this is plotting the water delta vs heat load and assuming a linear
trend-line. One thing I noticed is that the linear trendline didn't fit
very well over several curves particularly for the middle fan
scenarios. I'm not quite sure why, but for now I just assumed a linear
relationship to average the two heat loads.
To estimate water temperature, take your heat load in watts and follow it up vertically to
the fan scenario. When you cross that line, turn left and follow
it horizontally until it impacts the vertical axis on the left.
This temperature delta will be your number that you need.
To estimate your water temperature simply add this number to the
ambient.
To estimate a heat load you can use the following tools:
Power consumption vs. Heat Load - I just wanted to note that power
consumption is higher than actual heat load because you still loose
heat through air on the motherboard. If you want to be
conservative, you can just use the power consumption figures, but they
are likely a bit more heat than you really have. There are also
several different definitions of what "Load" really means, and you can
see using the Swiftech calculator, that every program is a bit
different as well. I haven't done much heat load testing yet
myself, but I "Think" we probably see something like 20% or so lost
through the air.
So what does this water temperature mean? You are cooling with the water that
leaves your radiator and enters your CPU block. So any
improvement in this number will directly translate into an improvement
in your CPU temperature. For example if your water temperature
delta is 10C and your loaded core temperature was 50C. If you
improved your water delta by 5C either by adding another radiator or
increasing your fan performance, your new core temperature will be 45C
assuming your ambient temperature remained the same.
To take it and break it down in a few additional curves:
These are the c/w values generated from the test system assuming a linear relationship between heat loads.
And by popular demand, here is a conversion of c/w to a 10C delta heat dissipated chart vs RPM.
I consider 10C delta average performance and a 5 C delta, high performance, but that's probably subjective.
And this is the same thing with the 5C delta.
480 Comparison
So, you might be wondering, how do the two King radiators perform.
While there are a few other quad radiators out there, I've only
tested the HWlabs 480GTX, and the TFC XChanger 480ER which I'll compare
here.
First up a quick look at c/w values, the closer you approach 0, the more significant the difference.
And converting that to 10C heat dissipated, this gives you more of a numbers look.
The
TFC480ER is dominating under 1880 RPMs, and the HWlabs 480GTX is
flexing it's high density muscle in the fans greater than 1880RPM.
The TFC480ER is dissipating approximately 29% more heat at the
Ultra Slow speed category, and about 27% less in the Ultra High speed
category.
Bottom line, at 1880RPM they are equal, anything slower and the TFC
XChanger 480 is superior, anything faster and the 480GTX is superior.
Personally I am a fan of the "Slow Speed" fans at around 1350RPM range,
so for me...the TFC 480ER would be the quad radiator of choice as it
would afford me about a 22% improvement over the 480GTX. In
addition the TFC 480ER provides a fair amount lower restriction for my
loop and will maintain higher flow rates and bleed faster which is helpful for quick bleeds in CPU block testing.
I'm currently soliciting a poll on XS to try and better understand what the user base is out there for fan speed/noise preference.
My results of that poll as of 7-4-08 were as follows: ( I will
update this as I get more votes in, currently showing 73 votes)
So from these polled survey results, most users prefer the 1350 Slow
Speed and 1550 Medium speed categories along with a somewhat suprising
high number of Ultra Slow speed users. During the poll I also had
quite a few people educate me in that 1000RPM is not slow enough, many
folks run fans down to 500, 700, and 800 RPM ranges. It appears
about 80% of the users surveyed would really benefit from the low fan
speed optimizations that this radiator provides.
The TFC XChanger 480ER provides EXCEPTIONAL Ultra Slow, Slow, and Medium speed fan performance!!
And for the last chart, here are some assumed heat load scenarios for
you to get a better sense of what all this c/w and watts dissipated
means for temperatures.
I also had some forum members ask
if they could see this against the PA120.3, so here that is. Keep
in mind the PA120.3 is only a triple radiator:
TFC 480ER No Shroud Water Temperature Estimator Spreadsheet
If you want
to tinker with heat loads and fan results, rather than using the charts, I've
created this quick little spreadsheet where you can enter in your own heat load
and ambient temperature. It will then show you the estimated water temperatures
based on the results I gathered above.
Note this is for informational and
educational purposes only.
TFC480EREstimator.zip
97-2003
Microsoft Excel (.xls) format
TFC Shroud Options
TFC also provided me with some of their universal shrouds which can be
used on any 120mm radiator, they come with a very nice antivabration
gasket and dual molex powered LED light. They also sell the LED
lights in several different colors.
Here is the packaging contents which includes screws for 25mm thickness fans mounted to the shrouds.
They are extremely nicely fabricated acrylic units, note the fine detail here.
I'm saving these shrouds for some later separate
fan/radiator experiments. These are exceptionally nice shrouds
and finally provide the water cooling community a quality and nice
looking universal shroud for any radiator, very nice!
Pros
- The NEW QUIET KING of ultra slow, slow, and medium speed fans! (Most thermally efficient quad radiator for the most common fans)
- Extremely high quality construction backed by a 3 year warranty
- Extremely low pressure drop means maximum flow rates for your water blocks, excellent for multiple block/radiator loops!
- Open finned design and double thickness is optimized for the highest efficiency using low speed fans
- Quad 120mm fan design offers EXTREME performance
- Copper tubes for maximum heat transfer
- Bleeding screw for installation bleeding assistance
- G1/4 threading offers compatibility with all standard G1/4 barbs.
- Matching TFC shroud options
Cons
- Large Quad Size
- Personally I like the larger sized radiators, but depending on the
intended installation location, you should plan for it.
- Cost - Like anything in life, premium
performance comes with a higher cost. Fortunately the radiator is
one of the few computer components you can continue to use and reuse
for many many years, so it is one of the few "long term" investments in computer performance you can make.
Bottom Line
The TFC X-Changer is an exceptionally well engineered and constructed
radiator. For users who prefer fans under 1880 RPM, it is THE
KING of dissipation for quad radiators that I have tested to date.
It is extremely well constructed and quality control is top
notch. Since I prefer fans of the slow speed or 1350RPM range,
this is the single best quad radiator I can use for my fan preference.
This is an amazing radiator!!
Where to buy
This radiator is a prototype, but I understand these will soon hit the
shelves of your favorite water cooling shops at around a retail
$199 USD includes:
- TFC XChanger 480ER
- 2X 3/8" ID x 1/2" OD Compression Fittings
- 1 50ml Feser Base corrosion blocker bottle
Here is a link to TFC website for details:
And I would expect the following vendors to carry the radiator when it comes to the US market:
|