EK-Quantum Vector² RTX 4090 Strix/TUF GPU Block Review 13

EK-Quantum Vector² RTX 4090 Strix/TUF GPU Block Review

Thermal Performance »

Liquid Flow Restriction

I use a Xylem D5 pump with a standalone reservoir, with the pump being powered through a direct SATA connection from a PSU used only for watercooling components and not part of the test system. The pump is controlled by an Aquacomputer Aquaero 6 XT in PWM mode. There is a calibrated in-line flow meter and Dwyer 490 Series 1 wet-wet manometer to measure the pressure drop of the component being tested. Every component is connected to the manometer by the way of soft tubing, compression fittings, and two T-fittings that have been accounted for when it comes to the liquid flow restriction in the loop.


There are a total of six blocks in this roundup, including a universal GPU block that I had tested at the last minute before the GPU had to be returned! Otherwise my plan was to get one entry each from five manufacturers who were able to provide units in time and so everything somehow worked out. All of these will get dedicated reviews, if not already have had them by the time you see this. As it stands, there are two groups of blocks and the EK-Quantum Vector² ends up in the more restrictive set. That new insert might perhaps help with thermal performance but the blocks with simpler cooling engines will of course be less restrictive.
Next Page »Thermal Performance
View as single page
Nov 27th, 2024 05:40 EST change timezone

New Forum Posts

Popular Reviews

Controversial News Posts