Ripple Measurements
You will see the ripple levels we measured on the NJ520's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Silverstone NJ520 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 12.0 mV | 10.7 mV | 9.3 mV | 4.9 mV | Pass |
---|
20% Load | 15.2 mV | 10.9 mV | 9.5 mV | 5.1 mV | Pass |
---|
30% Load | 19.9 mV | 10.9 mV | 9.2 mV | 5.2 mV | Pass |
---|
40% Load | 19.6 mV | 10.8 mV | 9.4 mV | 5.4 mV | Pass |
---|
50% Load | 21.5 mV | 11.1 mV | 9.5 mV | 6.1 mV | Pass |
---|
60% Load | 22.7 mV | 11.5 mV | 9.9 mV | 6.1 mV | Pass |
---|
70% Load | 23.3 mV | 13.0 mV | 10.7 mV | 6.5 mV | Pass |
---|
80% Load | 24.2 mV | 12.2 mV | 9.6 mV | 7.1 mV | Pass |
---|
90% Load | 26.3 mV | 12.9 mV | 14.9 mV | 7.9 mV | Pass |
---|
100% Load | 27.6 mV | 12.8 mV | 10.8 mV | 9.0 mV | Pass |
---|
110% Load | 29.2 mV | 13.2 mV | 11.1 mV | 9.3 mV | Pass |
---|
Crossload 1 | 15.2 mV | 12.6 mV | 10.5 mV | 19.2 mV | Pass |
---|
Crossload 2 | 27.6 mV | 12.2 mV | 10.2 mV | 7.9 mV | Pass |
---|
Excellent ripple filtering on all rails, and we didn't expect anything less from the platform since it uses topnotch components and is based on a cutting-edge design.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2