Test Setup
All measurements were performed using two Chroma 6314A mainframes equipped with the following electronic loads: six 63123A [350 W each], one 63102A [100 W x2], and one 63101A [200 W]. The aforementioned equipment is able to deliver 2500 W of load, and all loads are controlled by a custom-made software. The AC source is a Chroma 6530 capable of delivering up to 3 kW of power. We also used a Keysight DSOX3024A oscilloscope, a
Rigol DS2072A oscilloscope kindly sponsored by
Batronix, a
Picoscope 3424 oscilloscope, a Picotech
TC-08 thermocouple data logger, two Fluke multimeters (models 289 and 175), a Keithley 2015 THD 6.5 digit bench DMM, and a lab grade
N4L PPA1530 3-phase power analyzer along with a Yokogawa WT210 power meter. We also included a wooden box, which, along with some heating elements, was used as a hot box. Finally, we had at our disposal three more oscilloscopes (Rigol VS5042, Stingray DS1M12, and a second Picoscope 3424) and a Class 1
Bruel & Kjaer 2250-L G4 Sound Analyzer, equipped with a type 4189 microphone that features a 16.6-140 dBA-weighted dynamic range. You will find more details about our equipment and the review methodology we follow in
this article. We also conduct all of our tests at 40 °C - 45 °C ambient to simulate the environment seen inside a typical system more accurately, with 40 °C - 45 °C being derived from a standard ambient assumption of 23 °C and 17 °C - 22 °C being added for the typical temperature rise within a system.
To control the Chroma 6530 source, we use a
GPIB-USB controller, which avoids its incredibly picky Serial port. This controller was kindly provided by
Prologix.
To protect our super expensive Chroma AC source, we use an
OLS3000E online UPS with a capacity of 3000VA/2700W.
OLS3000E kindly provided by: |
|
Primary Rails Load Regulation
The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range.
5VSB Regulation
The following chart shows how the 5VSB rail deals with the loads we throw at it.
Hold-up Time
Hold-up time is a very important PSU characteristic and represents the amount of time, usually measured in milliseconds, a PSU can maintain output regulations as defined by the ATX specification without input power. In other words, it is the amount of time a system can continue to run without shutting down or rebooting during a power interruption. The ATX specification sets the minimum hold-up time to 17 ms with the maximum continuous output load.
According to the ATX specification, PWR_OK is a "power good" signal. This signal should be asserted as high on the 5V rail by the power supply to indicate that the +12V, 5V, and 3.3V outputs are within the regulation thresholds and that sufficient mains energy is stored by the APFC converter to guarantee a system's continuous operation for at least 17ms. Conversely, PWR_OK should be de-asserted to a low state, 0V, when any of the +12V, 5V, or 3.3V output voltages fall below the under-voltage threshold or when mains power has been removed for long enough to guarantee that a power supply isn't operating anymore. The AC loss to PWR_OK minimum hold-up time is set to 16 ms, which is less than the hold-up time described above, but the ATX specification also sets a PWR_OK inactive-to-DC loss delay that should be higher than 1 ms. This means that the AC loss to PWR_OK hold-up time should be lower than the PSU's overall hold-up time to ensure that the power supply doesn't send a power good signal once any of the +12V, 5V and 3.3V rails are out of spec.
In the following screenshots, the yellow line is representative of the +12V rail; the blue line is the mains signal and the green line is the "Power Good" signal.
The hold-up time is notably lower than required, but the power good signal is accurate.
Inrush Current
Inrush current, or switch-on surge, refers to the maximum, instantaneous input current drawn by an electrical device when it is first turned on. Because of the charging current of the APFC capacitor(s), PSUs produce a lot of inrush-current right as they are turned on. A lot of inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays, and bridge rectifiers; as a result, the lower a PSU's inrush current right as it is turned on, the better.
Irush current is as it should be for a 650 W PSU.
Load Regulation and Efficiency Measurements
The first set of tests revealed the stability of the voltage rails and the SF650P14PE's efficiency. The applied load was equal to (approximately) 10%-110% of the maximum load the PSU can handle, in 10% steps.
We conducted two additional tests. In the first test, we stressed the two minor rails (5V and 3.3V) with a high load while the load at +12V was only 0.10 A. This test reveals whether the PSU is Haswell ready or not. In the second test, we dialed the maximum load the +12V rail could handle while the load on the minor rails was minimal.
Load Regulation & Efficiency Testing Data - Super Flower SF-650P14PE |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Power (DC/AC) | Efficiency | Fan Speed | Fan Noise | Temp (In/Out) | PF/AC Volts |
---|
10% Load | 3.540A | 1.931A | 1.947A | 0.980A | 64.742W | 87.967% | 872 RPM | 34.3 dB(A) | 38.99°C | 0.745 |
---|
12.207V | 5.159V | 3.387V | 5.098V | 73.598W | 40.99°C | 230.23V |
20% Load | 8.113A | 2.917A | 2.924A | 1.176A | 129.809W | 91.804% | 872 RPM | 34.3 dB(A) | 39.31°C | 0.874 |
---|
12.194V | 5.146V | 3.381V | 5.087V | 141.398W | 41.53°C | 230.23V |
30% Load | 13.037A | 3.403A | 3.433A | 1.375A | 194.850W | 92.748% | 872 RPM | 34.3 dB(A) | 40.07°C | 0.924 |
---|
12.183V | 5.137V | 3.376V | 5.076V | 210.086W | 42.49°C | 230.23V |
40% Load | 17.963A | 3.896A | 3.913A | 1.575A | 259.776W | 93.113% | 872 RPM | 34.3 dB(A) | 40.62°C | 0.942 |
---|
12.171V | 5.127V | 3.371V | 5.065V | 278.991W | 43.35°C | 230.23V |
50% Load | 22.561A | 4.883A | 4.899A | 1.781A | 324.764W | 92.950% | 1000 RPM | 37.2 dB(A) | 41.02°C | 0.953 |
---|
12.158V | 5.115V | 3.367V | 5.054V | 349.396W | 43.90°C | 230.23V |
60% Load | 27.164A | 5.878A | 5.888A | 1.980A | 389.713W | 92.616% | 1190 RPM | 43.8 dB(A) | 41.41°C | 0.962 |
---|
12.147V | 5.100V | 3.361V | 5.042V | 420.784W | 44.59°C | 230.23V |
70% Load | 31.780A | 6.878A | 6.879A | 2.185A | 454.671W | 92.226% | 1320 RPM | 44.1 dB(A) | 42.02°C | 0.968 |
---|
12.133V | 5.088V | 3.358V | 5.029V | 492.994W | 45.62°C | 230.23V |
80% Load | 36.409A | 7.888A | 7.871A | 2.391A | 519.690W | 91.764% | 1518 RPM | 48.7 dB(A) | 42.79°C | 0.971 |
---|
12.120V | 5.074V | 3.353V | 5.018V | 566.333W | 46.78°C | 230.23V |
90% Load | 41.471A | 8.396A | 8.395A | 2.394A | 584.750W | 91.333% | 1660 RPM | 49.3 dB(A) | 43.80°C | 0.976 |
---|
12.108V | 5.065V | 3.347V | 5.010V | 640.237W | 48.08°C | 230.23V |
100% Load | 46.490A | 8.902A | 8.885A | 2.498A | 649.479W | 90.798% | 1720 RPM | 50.6 dB(A) | 44.96°C | 0.978 |
---|
12.095V | 5.056V | 3.341V | 5.000V | 715.299W | 49.89°C | 230.23V |
110% Load | 51.922A | 8.914A | 8.902A | 2.500A | 714.466W | 90.249% | 1760 RPM | 50.8 dB(A) | 46.08°C | 0.980 |
---|
12.081V | 5.050V | 3.336V | 4.993V | 791.664W | 51.42°C | 230.23V |
Crossload 1 | 0.102A | 12.009A | 12.005A | 0.004A | 103.317W | 86.182% | 1220 RPM | 43.3 dB(A) | 44.20°C | 0.846 |
---|
12.197V | 5.094V | 3.405V | 5.101V | 119.882W | 47.77°C | 230.23V |
Crossload 2 | 54.128A | 1.002A | 1.003A | 1.002A | 668.141W | 91.474% | 1720 RPM | 50.6 dB(A) | 45.49°C | 0.978 |
---|
12.094V | 5.109V | 3.329V | 5.050V | 730.415W | 47.98°C | 230.25V |
Load regulation is tight enough for this category, especially at +12V, which is the most important rail of all. Efficiency is pretty high and peaks at over 93% at 40% load. This PSU also doesn't run into any problems at very high operating temperatures, even while delivering its full load over prolonged periods of time. However, once pushed, the small diameter fan can be really loud. A semi-passive operation would allow for a much quieter operation at light and possibly moderate loads.