Antec Signature Titanium 1000 W Review - Return of the Legend 28

Antec Signature Titanium 1000 W Review - Return of the Legend

Cross Load Tests »

Test Setup



Primary Rails Load Regulation

The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range. Tight load regulation is an important characteristic for every power supply since it allows for constant voltage levels despite changes in load.






5VSB Regulation



Hold-up Time

Hold-up time represents the amount of time, usually measured in milliseconds, a PSU can maintain output regulations as defined by the ATX specification without input power. Hold-up time is the amount of time the system can continue to run without shutting down or rebooting during a power interruption. In the following screenshots, the blue line is the mains signal, the green line the "Power Good" signal, and the yellow line the +12V rail.







Inrush Current

Inrush current, or switch-on surge, refers to the maximum instantaneous input current drawn by an electrical device when it is first turned on. Large enough inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays, and bridge rectifiers. As a result, the lower the inrush current of a PSU right as it is turned on, the better.



10-110% Load Testing

These tests reveal the ST1000's load regulation and efficiency levels under high ambient temperatures. They also show how the fan-speed profile behaves under tough operating conditions.

Load Regulation & Efficiency Testing Data - Antec Signature 1000 Titanium
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
10% Load6.368A1.962A1.962A1.006A100.007W92.043%0 RPM<6.0 dB(A)42.80°C0.822
12.312V5.097V3.367V4.969V108.652W39.84°C230.24V
20% Load13.739A2.944A2.942A1.211A200.038W94.459%0 RPM<6.0 dB(A)44.47°C0.921
12.311V5.094V3.365V4.955V211.772W40.77°C230.24V
30% Load21.448A3.437A3.434A1.416A300.012W95.006%632 RPM20.1 dB(A)41.46°C0.953
12.307V5.093V3.363V4.943V315.781W45.76°C230.24V
40% Load29.133A3.927A3.926A1.623A399.670W95.106%636 RPM20.1 dB(A)41.62°C0.967
12.305V5.091V3.361V4.930V420.237W46.55°C230.24V
50% Load36.511A4.913A4.913A1.831A499.802W94.942%670 RPM23.1 dB(A)42.09°C0.975
12.306V5.088V3.358V4.917V526.427W47.87°C230.23V
60% Load43.894A5.901A5.904A2.000A599.739W94.712%724 RPM24.5 dB(A)42.57°C0.981
12.305V5.085V3.355V4.905V633.225W48.85°C230.23V
70% Load51.238A6.888A6.891A2.250A699.654W94.378%783 RPM27.0 dB(A)43.42°C0.984
12.306V5.083V3.353V4.890V741.333W50.29°C230.23V
80% Load58.646A7.878A7.878A2.461A800.179W94.012%853 RPM29.8 dB(A)43.65°C0.987
12.307V5.080V3.351V4.877V851.149W51.11°C230.24V
90% Load66.379A8.372A8.360A2.465A899.442W93.662%925 RPM32.2 dB(A)44.22°C0.989
12.307V5.078V3.349V4.870V960.302W52.50°C230.23V
100% Load73.943A8.869A8.872A3.096A999.873W93.194%1005 RPM34.2 dB(A)45.25°C0.990
12.309V5.075V3.347V4.846V1072.891W54.31°C230.24V
110% Load82.062A8.869A8.879A3.100A1099.889W92.750%1316 RPM41.6 dB(A)46.55°C0.991
12.310V5.074V3.345V4.840V1185.863W56.34°C230.23V
Crossload 10.101A15.000A14.998A0.000A127.749W89.546%814 RPM28.4 dB(A)42.16°C0.873
12.335V5.077V3.357V5.009V142.663W47.51°C230.25V
Crossload 283.018A1.000A1.001A1.000A1035.050W93.422%1008 RPM35.2 dB(A)45.61°C0.990
12.307V5.085V3.352V4.906V1107.930W54.81°C230.24V

Light Load Testing

In the following tests, we measure the ST1000's efficiency at loads significantly lower than 10 percent of its maximum capacity (the lowest load the 80 PLUS standard measures). This is important for when a PC is idle with its power-saving features turned on.

Efficiency at Low Loads - Antec Signature 1000 Titanium
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
12.835A0.490A0.489A0.200A40.030W86.095%0 RPM<6.0 dB(A)0.627
12.303V5.106V3.373V4.996V46.495W230.23V
24.038A0.980A0.979A0.401A59.981W89.372%0 RPM<6.0 dB(A)0.717
12.304V5.101V3.370V4.989V67.114W230.23V
35.246A1.471A1.472A0.602A80.013W91.143%0 RPM<6.0 dB(A)0.784
12.306V5.098V3.368V4.981V87.788W230.24V
46.455A1.962A1.960A0.804A100.045W92.204%0 RPM<6.0 dB(A)0.822
12.307V5.098V3.368V4.974V108.504W230.24V

Ultra-light Load Testing

The applied load in this test is only 10 W for PSUs with 500 W and less capacity. For stronger units, we dial in 2% of the maximum-rated capacity. We only run this test with 115 V input.

Efficiency at Low Loads - Antec Signature 1000 Titanium
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
11.464A0.265A0.266A0.053A20.509W77.492%0 RPM<6.0 dB(A)0.813
12.289V5.111V3.375V5.001V26.466W115.12V

Efficiency

Using the results we gathered so far, we plotted a chart showing the ST1000's efficiency at low loads and loads from 10 to 110 percent of its maximum-rated capacity.



As you can see in the graphs above, efficiency is very high for all loads.

5VSB Efficiency

5VSB Efficiency - Antec Signature 1000 Titanium
Test #5VSBPower (DC/AC)EfficiencyPF/AC Volts
10.100A0.512W68.176%0.024
5.118V0.751W230.22V
20.250A1.279W74.664%0.053
5.114V1.713W230.22V
30.550A2.809W78.508%0.106
5.107V3.578W230.23V
41.000A5.096W80.227%0.174
5.096V6.352W230.22V
51.500A7.626W79.870%0.234
5.083V9.548W230.22V
63.001A15.138W80.044%0.337
5.045V18.912W230.22V


The 5VSB rail is efficient enough.

Power Consumption in Idle and Standby

Idle / Standby - Antec Signature 1000 Titanium
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.288V5.112V3.376V5.004V4.488W0.128
230.3V
Standby0.093W0.003
230.3V

Fan RPM, Delta Temperature and Output Noise

The following results were obtained at 37–47 °C ambient.





The following results were obtained at 30–32 °C ambient.