All measurements were performed using two Chroma 6314A mainframes equipped with the following electronic loads: six 63123A [350 W each], one 63102A [100 W x2], and one 63101A [200 W]. The aforementioned equipment is able to deliver 2500 W of load, and all loads are controlled by a custom-made software. We also used a Picoscope 3424 oscilloscope, a Picotech TC-08 thermocouple data logger, a Fluke 175 multimeter, and a Yokogawa WT210 power meter. We also included a wooden box, which, along with some heating elements, was used as a hot box. Finally, we had at our disposal four more oscilloscopes (Rigol 1052E and VS5042, Stingray DS1M12, a second Picoscope 3424), and a CEM DT-8852 sound level meter. You will find more details about our equipment and the review methodology we follow in this article,. Finally, we conduct all of our tests at 40°C-45°C ambient to simulate the environment seen inside a typical system as accurately as possible, with 40°C-45°C being derived from a standard ambient assumption of 23°C and 17°C-22°C being added for the typical temperature rise within a system.
Primary Rails Voltage Regulation
The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range.
5VSB Regulation
The following chart shows how the 5VSB rail deals with the load we throw at it.
Hold-up Time
Hold-up time is a very important PSU characteristic. It represents the amount of time a PSU can maintain output regulations as defined by the ATX spec without input power and is usually measured in milliseconds. In other words, it is the amount of time the system can continue to run without shutting down or rebooting during a power interruption. The ATX spec sets the minimum hold-up time to 16 ms with the maximum continuous output load. In the following screenshot, the blue line is the mains signal and the yellow line is the "Power Good" signal. The latter is de-asserted to a low state when any of the +12V, 5V, or 3.3V output voltages fall below the undervoltage threshold, or after the mains power has been removed for a sufficiently long time to guarantee that the PSU cannot operate anymore.
The measured hold-up time is close to the minimum allowed time the ATX spec specifies, so we won't whine a lot about its failure to pass this test. However, we will still deduct some performance points for missing the 16 ms threshold by 1 ms.
Inrush Current
Inrush current or switch-on surge refers to the maximum, instantaneous input-current drawn by an electrical device when first turned on. Because of the charging current of the APFC capacitor(s), PSUs produce large inrush-current right as they are turned on. Large inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays and bridge rectifiers; as a result, the lower the inrush current of a PSU right as it is turned on, the better.
The registered inrush current was higher than it would normally be for a medium-capacity PSU, which is pretty strange because the NTC thermistor is quite large. But 40 A doesn't pose a threat to properly working circuit breakers and fuses, so you have nothing to worry about.
Voltage Regulation and Efficiency Measurements
The first set of tests revealed the stability of the voltage rails and the efficiency of the V550S. The applied load was equal to (approximately) 20%, 40%, 50%, 60%, 80%, 100% and 110% of the maximum load that the PSU can handle. We conducted two additional tests. In the first test, we stressed the two minor rails (5V and 3.3V) with a high load while the load at +12V was only 0.10 A. This test reveals whether the PSU is Haswell ready or not. In the second test, we dialed the maximum load that the +12V rail could handle while the load on the minor rails was minimal.
Voltage Regulation & Efficiency Testing Data Cooler Master V550S
Test
12 V
5 V
3.3 V
5VSB
Power (DC/AC)
Efficiency
Fan Speed
Fan Noise
Temp (In/Out)
PF/AC Volts
20% Load
7.179A
1.993A
1.983A
1.000A
109.72W
92.39%
630 RPM
32.7 dBA
37.59°C
0.866
12.282V
5.010V
3.321V
4.980V
118.76W
41.90°C
230.3V
40% Load
14.727A
4.002A
3.988A
1.205A
219.76W
93.29%
797 RPM
33.5 dBA
38.51°C
0.944
12.262V
4.998V
3.307V
4.969V
235.57W
43.28°C
230.2V
50% Load
18.385A
5.004A
4.999A
1.615A
274.70W
92.75%
1203 RPM
37.8 dBA
39.93°C
0.956
12.252V
4.989V
3.299V
4.950V
296.16W
45.08°C
230.3V
60% Load
22.049A
6.015A
6.012A
2.025A
329.69W
92.25%
1626 RPM
42.4 dBA
41.18°C
0.964
12.242V
4.984V
3.293V
4.935V
357.40W
46.85°C
230.2V
80% Load
29.558A
8.044A
8.050A
2.440A
439.60W
91.17%
2032 RPM
47.3 dBA
42.75°C
0.972
12.221V
4.971V
3.279V
4.914V
482.16W
48.98°C
230.2V
100% Load
37.903A
9.067A
9.086A
2.545A
549.53W
89.95%
2047 RPM
47.5 dBA
44.36°C
0.976
12.199V
4.960V
3.268V
4.904V
610.90W
51.09°C
230.1V
110% Load
42.461A
9.073A
9.097A
2.551A
604.50W
89.32%
2047 RPM
47.5 dBA
45.86°C
0.976
12.184V
4.956V
3.264V
4.898V
676.75W
53.40°C
230.0V
Crossload 1
0.097A
12.004A
12.004A
0.004A
100.75W
86.62%
1730 RPM
44.7 dBA
42.87°C
0.861
12.280V
4.993V
3.299V
5.030V
116.31W
48.87°C
230.3V
Crossload 2
44.986A
1.001A
1.002A
1.001A
561.65W
90.36%
2047 RPM
47.5 dBA
44.45°C
0.976
12.191V
4.972V
3.290V
4.945V
621.55W
51.14°C
230.1V
Efficiency was crazily high for a Gold unit, especially up to our 60% load test, but it started to decrease at higher loads, which goes to show that this unit's efficiency is tuned around lower loads. Also, despite the 40°C limit on papers, the PSU had no problem whatsoever delivering its full power and even more at 45°C-46°C. This PSU runs a fairly relaxed fan profile, and we had to push the unit really hard for the control circuit to nearly maximize RPM, where the noise output was significant. The fan this small unit is equipped with is powerful, too strong for such a highly efficient PSU, which is the reason for its unusually low RPM under normal conditions. Finally, voltage regulation on all rails was very good—the +12V rail registered a reading within 1%.