Corsair Gaming Series GS800 800 W Review 6

Corsair Gaming Series GS800 800 W Review

Transient Response Tests »

Test Setup

All measurements are performed utilizing a custom designed and built load tester, called Faganas, which is able to stress PSUs up to 1800 Watts. We also use a DS1M12 (Stingray) oscilloscope, a CHY 502 thermometer, a Fluke 175 multimeter and an Instek GPM-8212 power meter. Furthermore, in our setup we have included a wooden box, which along with a heating element is used as a Hot Box. Finally, we have at our disposal three electronic loads (Array 3711A, 300W), a Rigol 1052E oscilloscope and a CEM DT-8852 sound level meter. In the near future we plan to acquire six additional loads to complete our new test set up, which with the help of our custom built software will have the same capabilities with the, ultra expensive, Chroma ATEs. In this article you will find more details about our equipment and the review methodology we follow.

Voltage Regulation Charts

The following charts show the voltage values of the main rails, recorded over a range from 60W to the maximum specified load, and the deviation (in percent), when compared with the voltage values at 60W load.







Efficiency Chart

In this chart you will find the efficiency of GS800 at low loads and at loads equal to 20-100% of PSU’s maximum rated load.



Voltage Regulation and Efficiency Measurements

The first set of tests reveals the stability of voltage rails and the efficiency of the PSU. The applied load equals to (approximately) 20%, 40%, 50%, 60%, 80% and 100%, of the maximum load that the PSU can handle. In addition, we conduct two more tests. In the first we stress the two minor rails (5V & 3.3V) with the maximum load that our tester can apply to these rails, while the load at +12V is only 2A and in the second test we dial the maximum load that +12V can handle while load at minor rails is minimum.

Voltage Regulation & Efficiency Testing Data
Corsair GS800
Test12 V5 V3.3 VPower
(DC/AC)
EfficiencyTemp
(In/Out)
PF/AC
Volts
20% Load12.024A2.003A2.182A163.49W85.13 %43.0 °C0.901
12.146V5.079V3.332V192.05W46.8 °C232.2V
40% Load23.507A4.906A6.042A328.98W86.49 %46.1 °C0.943
12.103V5.023V3.283V380.35W51.3 °C232.4V
50% Load29.429A6.829A8.083A415.51W86.26 %46.3 °C0.954
12.068V4.990V3.252V481.70W51.8 °C232.1V
60% Load35.211A6.813A8.075A484.57W86.42 %47.2 °C0.958
12.055V4.983V3.247V560.75W54.0 °C233.4V
80% Load46.733A8.897A9.780A636.64W85.23 %48.8 °C0.969
12.009V4.942V3.216V747.00W57.5 °C228.7V
100% Load60.933A8.879A9.763A803.65W83.67 %50.0 °C0.977
11.959V4.922V3.201V960.50W60.8 °C228.5V
Crossload 11.972A19.672A17.071A173.17W72.47 %49.2 °C0.915
12.083V4.827V3.186V238.95W55.4 °C231.1V
Crossload 265.796A1.968A2.160A805.66W84.76 %51.6 °C0.977
11.987V5.020V3.281V950.50W63.8 °C229.3V
For a plain 80PLUS certified PSU efficiency is high enough. Voltage regulation at +12V is within 2% deviation, at 5V it is a little above 3% and for 3.3V is 4.22%. All in all voltage regulation is fair for the category of the PSU and especially the +12V rail, which is the most important, maintains a good voltage regulation. Finally, with 20% load PF is very low but at 40% load it rises to normal levels. The 80PLUS certification, with which this PSU is compliant, requires the power factor to be at least 0.9 at 100% load, something that of course is easy achievable by the GS800.

Efficiency at Low Loads

In the next tests, we measure the efficiency of GS800 at loads much lower than 20% of its maximum rated load (the lowest load that the 80 Plus Standard measures). The loads that we dial are (approximately) 40, 65 and 90W. This is important for scenarios in which a typical office PC is in idle with power saving turned on.

Efficiency at Low Loads
Corsair GS800
Test #12 V5 V3.3 VPower
(DC/AC)
EfficiencyPF/AC
Volts
11.968A2.014A2.197A41.56W69.38 %0.747
12.179V5.089V3.343V59.90W230.4V
23.906A2.010A2.196A65.09W75.51 %0.819
12.169V5.086V3.342V86.20W229.8V
36.049A2.010A2.194A91.13W81.04 %0.853
12.164V5.084V3.340V112.45W230.2V
Efficiency at low loads is equally low. Only with 91W load the PSU manages to hit above 80% efficiency. For a typical 800 W 80PLUS certified PSU that is the norm, so no surprises here.

Power Consumption in Idle & Standby

In the table below you will find the power consumption and the voltage values of all rails (except -12V), when the PSU is in idle mode (On but without any load at its rails) and the power consumption when the PSU is in standby (without any load at 5VSB).

Idle / Standby
Corsair GS800
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.199V5.126V3.369V5.141V8.150W0.210
232.3V
Standby 0.82W0.024
232.2V
In standby mode energy consumption is below the 1W limit, so GS800 is ErP Lot 6 compliant.
Next Page »Transient Response Tests
View as single page
Dec 23rd, 2024 09:41 EST change timezone

New Forum Posts

Popular Reviews

Controversial News Posts