Ripple Measurements
You will see the ripple levels we measured on the rails of the RM650i in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Corsair RM650i |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 4.5 mV | 5.2 mV | 5.3 mV | 4.4 mV | Pass |
---|
20% Load | 5.6 mV | 5.6 mV | 5.7 mV | 4.8 mV | Pass |
---|
30% Load | 6.8 mV | 9.1 mV | 7.0 mV | 8.0 mV | Pass |
---|
40% Load | 7.1 mV | 10.4 mV | 8.6 mV | 10.3 mV | Pass |
---|
50% Load | 7.5 mV | 6.3 mV | 8.3 mV | 6.4 mV | Pass |
---|
60% Load | 7.9 mV | 6.4 mV | 7.6 mV | 6.9 mV | Pass |
---|
70% Load | 8.0 mV | 6.7 mV | 7.4 mV | 7.4 mV | Pass |
---|
80% Load | 8.9 mV | 7.0 mV | 8.7 mV | 7.7 mV | Pass |
---|
90% Load | 10.0 mV | 7.2 mV | 8.4 mV | 8.2 mV | Pass |
---|
100% Load | 12.3 mV | 8.9 mV | 10.4 mV | 9.5 mV | Pass |
---|
110% Load | 14.4 mV | 9.0 mV | 11.0 mV | 10.4 mV | Pass |
---|
Crossload 1 | 6.8 mV | 7.5 mV | 8.4 mV | 6.6 mV | Pass |
---|
Crossload 2 | 12.0 mV | 8.4 mV | 9.9 mV | 8.1 mV | Pass |
---|
Ripple suppression is jaw dropping! This unit is easily capable of competing with Super Flower's high-end implementations. We simply couldn't ask for better results here.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2