Ripple Measurements
You will see the ripple levels we measured on the DQ1250's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Deepcool DQ1250 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 12.3 mV | 20.7 mV | 20.3 mV | 9.6 mV | Pass |
---|
20% Load | 23.3 mV | 22.0 mV | 19.8 mV | 10.3 mV | Pass |
---|
30% Load | 37.5 mV | 22.7 mV | 20.9 mV | 10.2 mV | Pass |
---|
40% Load | 28.7 mV | 24.2 mV | 21.2 mV | 11.8 mV | Pass |
---|
50% Load | 30.4 mV | 25.1 mV | 25.3 mV | 15.7 mV | Pass |
---|
60% Load | 29.9 mV | 26.9 mV | 25.8 mV | 19.0 mV | Pass |
---|
70% Load | 31.8 mV | 28.5 mV | 29.6 mV | 20.4 mV | Pass |
---|
80% Load | 33.7 mV | 30.9 mV | 32.5 mV | 23.4 mV | Pass |
---|
90% Load | 37.1 mV | 32.1 mV | 36.2 mV | 27.0 mV | Pass |
---|
100% Load | 40.8 mV | 34.3 mV | 39.7 mV | 31.0 mV | Pass |
---|
110% Load | 45.2 mV | 36.0 mV | 40.2 mV | 33.9 mV | Pass |
---|
Crossload 1 | 17.6 mV | 25.8 mV | 22.4 mV | 11.0 mV | Pass |
---|
Crossload 2 | 40.2 mV | 30.4 mV | 33.7 mV | 30.2 mV | Pass |
---|
Ripple suppression on the +12V rail was very good, but could be better on every other rail. Especially the 3.3V rail could do with less ripple. However, the +12V rail is the one that counts, and it performed incredibly well.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2