EVGA SuperNOVA 650 G2 Review 7

EVGA SuperNOVA 650 G2 Review

Performance Rating, Performance per Dollar, Noise & Efficiency Rating »

Ripple Measurements

You will see the ripple levels we measured on the SuperNOVA 650 G2's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - EVGA SuperNOVA 650 G2
Test12 V5 V3.3 V5VSBPass/Fail
10% Load4.0 mV5.2 mV7.2 mV4.3 mVPass
20% Load5.3 mV5.0 mV7.5 mV4.3 mVPass
30% Load6.2 mV5.1 mV8.0 mV4.7 mVPass
40% Load7.0 mV4.7 mV8.1 mV5.0 mVPass
50% Load7.6 mV5.2 mV8.7 mV4.7 mVPass
60% Load8.8 mV5.4 mV9.9 mV5.1 mVPass
70% Load9.4 mV5.8 mV9.7 mV5.9 mVPass
80% Load9.6 mV6.2 mV10.2 mV7.5 mVPass
90% Load10.1 mV6.5 mV12.4 mV7.5 mVPass
100% Load11.0 mV7.7 mV14.3 mV8.7 mVPass
110% Load11.6 mV7.8 mV14.4 mV9.6 mVPass
Crossload 16.0 mV6.2 mV7.9 mV10.3 mVPass
Crossload 210.8 mV7.8 mV14.0 mV7.3 mVPass
Ripple suppression is jaw-dropping on all rails. Super Flower did an amazing job with the new Leadex platform, which these graphs clearly mirror. If you want a ripple-proof PSU, getting a unit by Super Flower is a pretty safe bet.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2