EVGA SuperNOVA G2 850 W Review 4

EVGA SuperNOVA G2 850 W Review

Performance Rating, Performance per Dollar & Efficiency Rating »

Ripple Measurements

You will see the ripple levels we measured on the G2-850's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - EVGA G2-850
Test12 V5 V3.3 V5VSBPass/Fail
10% Load5.6 mV4.6 mV7.4 mV4.7 mVPass
20% Load6.7 mV4.8 mV7.6 mV4.8 mVPass
30% Load7.8 mV5.1 mV8.0 mV4.5 mVPass
40% Load8.4 mV5.3 mV9.2 mV4.8 mVPass
50% Load10.1 mV5.4 mV8.8 mV5.2 mVPass
60% Load10.4 mV5.8 mV9.0 mV5.5 mVPass
70% Load10.7 mV6.1 mV10.0 mV5.7 mVPass
80% Load11.5 mV6.5 mV10.9 mV7.6 mVPass
90% Load12.7 mV6.8 mV11.8 mV8.0 mVPass
100% Load12.7 mV8.1 mV12.3 mV10.4 mVPass
110% Load13.7 mV7.6 mV13.1 mV10.4 mVPass
Crossload 16.7 mV6.5 mV8.7 mV9.6 mVPass
Crossload 212.6 mV6.6 mV12.9 mV6.8 mVPass
Ripple suppression is one of the many strong points of this unit and its platform. Super Flower's implementations are among the best in this area, and the G2-850 is clear proof of this. Close to 10 mV ripple on all rails with full load and at over 47°C ambient is definitely something we don't see often!

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating, Performance per Dollar & Efficiency Rating
View as single page
Nov 25th, 2024 09:39 EST change timezone