Ripple Measurements
You will see the ripple levels we measured on the G2-850's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - EVGA G2-850 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 5.6 mV | 4.6 mV | 7.4 mV | 4.7 mV | Pass |
---|
20% Load | 6.7 mV | 4.8 mV | 7.6 mV | 4.8 mV | Pass |
---|
30% Load | 7.8 mV | 5.1 mV | 8.0 mV | 4.5 mV | Pass |
---|
40% Load | 8.4 mV | 5.3 mV | 9.2 mV | 4.8 mV | Pass |
---|
50% Load | 10.1 mV | 5.4 mV | 8.8 mV | 5.2 mV | Pass |
---|
60% Load | 10.4 mV | 5.8 mV | 9.0 mV | 5.5 mV | Pass |
---|
70% Load | 10.7 mV | 6.1 mV | 10.0 mV | 5.7 mV | Pass |
---|
80% Load | 11.5 mV | 6.5 mV | 10.9 mV | 7.6 mV | Pass |
---|
90% Load | 12.7 mV | 6.8 mV | 11.8 mV | 8.0 mV | Pass |
---|
100% Load | 12.7 mV | 8.1 mV | 12.3 mV | 10.4 mV | Pass |
---|
110% Load | 13.7 mV | 7.6 mV | 13.1 mV | 10.4 mV | Pass |
---|
Crossload 1 | 6.7 mV | 6.5 mV | 8.7 mV | 9.6 mV | Pass |
---|
Crossload 2 | 12.6 mV | 6.6 mV | 12.9 mV | 6.8 mV | Pass |
---|
Ripple suppression is one of the many strong points of this unit and its platform. Super Flower's implementations are among the best in this area, and the G2-850 is clear proof of this. Close to 10 mV ripple on all rails with full load and at over 47°C ambient is definitely something we don't see often!
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2