Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (10 A at +12V, 5 A at 5V, 5 A at 3.3V, and 0.5 A at 5VSB) is applied to the PSU for 200 ms while the latter is working at a 20% load state. In the second scenario, the PSU, while working at 50% load, is hit by the same transient load. In both tests, we measure the voltage drops that the transient load causes using our oscilloscope. The voltages should remain within the regulation limits defined by the ATX specification. We must stress here that the above tests are crucial since they simulate transient loads that a PSU is very likely to handle (e.g., booting a RAID array, an instant 100% load of CPU/VGAs, etc.) We call these tests "Advanced Transient Response Tests", and they are designed to be very tough to master, especially for PSUs with capacities lower than 500 W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V12.051V11.817V1.94%Pass
5 V5.046V4.930V2.30%Pass
3.3 V3.313V3.167V4.41%Pass
5VSB4.997V4.941V1.12%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V11.983V11.881V0.85%Pass
5 V4.997V4.874V2.46%Pass
3.3 V3.277V3.120V4.79%Fail
5VSB4.949V4.889V1.21%Pass


During the first test, the +12V registered a large deviation, but the deviation dropped well below 1% on the second test. Also, the time it takes the +12V and 5V rails to stabilize their voltages after the application of the transient load is quite long. The weak chain here is the 3.3V rail; its voltage dropped below 3.2V during the first test. It even failed to keep its voltage above the minimum allowed limit during the second test. The PSU didn't score very high on these tests.
Below, you will find the oscilloscope screenshots that we took during Advanced Transient Response Testing.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

We measure the response of the PSU in simpler scenarios of transient loads - during the power-on phase of the PSU - in the next set of tests. In the first test, we turn the PSU off, dial the maximum current that the 5VSB can output, and then switch on the PSU. In the second test, we dial the maximum load that +12V can handle and we start the PSU while the PSU is in standby mode. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's on/off switch), we dial the maximum load that the +12V rail can handle before switching the PSU on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for 12V is 13.2V and for 5V is 5.5V).


The 5VSB rail registered a small spike that is a little above the nominal voltage of this rail, and the +12V didn't register any voltage overshoots on both tests. Only in the last test did the slope make a noticeable dive at around 4 V.