Ripple Measurements

You will see the ripple levels we measured on the rails of the HGX550 in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - FSP HGX550
Test12 V5 V3.3 V5VSBPass/Fail
10% Load46.1 mV9.5 mV8.5 mV12.4 mVPass
20% Load26.4 mV10.8 mV9.1 mV16.2 mVPass
30% Load28.1 mV10.0 mV9.4 mV17.5 mVPass
40% Load31.2 mV11.2 mV9.6 mV18.0 mVPass
50% Load28.2 mV12.0 mV10.2 mV20.8 mVPass
60% Load32.9 mV13.3 mV12.1 mV22.7 mVPass
70% Load37.3 mV15.1 mV12.9 mV23.4 mVPass
80% Load42.3 mV17.1 mV15.5 mV26.4 mVPass
90% Load44.7 mV17.3 mV15.0 mV26.8 mVPass
100% Load49.6 mV19.7 mV17.0 mV29.5 mVPass
110% Load50.9 mV20.0 mV17.5 mV29.6 mVPass
Crossload 139.5 mV16.5 mV18.8 mV13.0 mVPass
Crossload 242.6 mV17.0 mV11.8 mV19.8 mVPass
Ripple suppression is pretty good at 5V and 3.3V and decent at +12V and 5VSB. We can't be that picky since this PSU doesn't belong to the high-end category. After all, 50 mV of ripple at +12V in such tough conditions doesn't leave much room for complaint.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2