Ripple Measurements
You will see the ripple levels we measured on the rails of the HGX550 in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - FSP HGX550 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 46.1 mV | 9.5 mV | 8.5 mV | 12.4 mV | Pass |
---|
20% Load | 26.4 mV | 10.8 mV | 9.1 mV | 16.2 mV | Pass |
---|
30% Load | 28.1 mV | 10.0 mV | 9.4 mV | 17.5 mV | Pass |
---|
40% Load | 31.2 mV | 11.2 mV | 9.6 mV | 18.0 mV | Pass |
---|
50% Load | 28.2 mV | 12.0 mV | 10.2 mV | 20.8 mV | Pass |
---|
60% Load | 32.9 mV | 13.3 mV | 12.1 mV | 22.7 mV | Pass |
---|
70% Load | 37.3 mV | 15.1 mV | 12.9 mV | 23.4 mV | Pass |
---|
80% Load | 42.3 mV | 17.1 mV | 15.5 mV | 26.4 mV | Pass |
---|
90% Load | 44.7 mV | 17.3 mV | 15.0 mV | 26.8 mV | Pass |
---|
100% Load | 49.6 mV | 19.7 mV | 17.0 mV | 29.5 mV | Pass |
---|
110% Load | 50.9 mV | 20.0 mV | 17.5 mV | 29.6 mV | Pass |
---|
Crossload 1 | 39.5 mV | 16.5 mV | 18.8 mV | 13.0 mV | Pass |
---|
Crossload 2 | 42.6 mV | 17.0 mV | 11.8 mV | 19.8 mV | Pass |
---|
Ripple suppression is pretty good at 5V and 3.3V and decent at +12V and 5VSB. We can't be that picky since this PSU doesn't belong to the high-end category. After all, 50 mV of ripple at +12V in such tough conditions doesn't leave much room for complaint.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2