Mushkin HP-580 AP Review 13

Mushkin HP-580 AP Review

Performance »

PSU Inside


This little sticker covers one of the screws that need to be removed to open the case. If you value your warranty, leave the sticker alone.


The PSU insides look very compact, the heatsinks are also rather small, yet the unit is quiet as we will see later.

Test Equipment

  • The PSU is connected to an APC SmartUPS which supplies clean 220V input.
  • AC current is measured using a Peaktech 4010 desktop RS232 multimeter with 0.02A accuracy.
  • To measure DC output voltages of the PSU we use a Keithley 2700 6.5 digit data acquisition system. All three input voltages are measured at the same time using a solid state switching system.
  • Power Factor is measured using a generic Power Efficiency Meter.
  • Measurements for Ripple Voltage were obtained using a 100 MHz Tektronix TDS224 Digital Storage Oscilloscope.


Fan noise measurements are performed with an IEC Type 2 Sound level meter and this setup.
It consists of three high-power resistors and a Socket A motherboard. The motherboard creates a small load which makes sure the PSU turns on (some PSUs require a minimum load). Since there is no hardware installed in the motherboard, its power draw is negligible. The three resistors create a static load of 320W (120W @ 12V + 50W @ 5V + 150W @ 12V) - a typical high-performance system. This setup is also used to determine the power conversion efficiency of the PSU.
Next Page »Performance
View as single page