All measurements are performed utilizing ten electronic loads (seven Array 3711A, 300W each, and three Array 3710A, 150W each), which are able to deliver over 2500W of load and are controlled by a custom made software. We also use a Picoscope 3424 oscilloscope, a CHY 502 thermometer, a Fluke 175 multimeter and an Instek GPM-8212 power meter. Furthermore, in our setup we have included a wooden box, which along with a heating element is used as a Hot Box. Finally, we have at our disposal four more oscilloscopes (Rigol 1052E and VS5042, Stingray DS1M12 and a second Picoscope 3424) and a CEM DT-8852 sound level meter. In this article you will find more details about our equipment and the review methodology we follow. Finally, if the manufacturer states that the maximum operating temperature of the test unit is only 40°C then we try to stay near this temperature, otherwise we crank up the heat inside the hotbox up to 50°C.

Voltage Regulation Charts

The following charts show the voltage values of the main rails, recorded over a range from 60W to the maximum specified load, and the deviation (in percent) for the same load range.







5VSB Regulation Chart

The following chart shows how the 5VSB rail deals with the load we throw at it.


Efficiency Chart

In this chart you will find the efficiency of ZS 650W at low loads and at loads equal to 20-100% of PSU's maximum rated load.



Voltage Regulation and Efficiency Measurements

The first set of tests reveals the stability of voltage rails and the efficiency of ZS 650W. The applied load equals to (approximately) 20%, 40%, 50%, 60%, 80% and 100%, of the maximum load that the PSU can handle. In addition, we conduct two more tests. In the first we stress the two minor rails (5V & 3.3V) with a high load, while the load at +12V is only 2A and in the second test we dial the maximum load that +12V can handle while load at minor rails is minimal.

Voltage Regulation & Efficiency Testing Data
OCZ ZS 650W
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyTemp
(In/Out)
PF/AC
Volts
20% Load8.897A1.943A1.947A0.982A130.00W84.47%38.9°C0.904
12.184V5.145V3.390V5.091V153.90W43.1°C229.7V
40% Load18.226A3.914A3.928A1.184A260.00W86.39%40.7°C0.944
12.115V5.109V3.360V5.064V300.95W47.0°C230.7V
50% Load22.798A4.901A4.934A1.590A325.00W86.28%42.3°C0.954
12.085V5.100V3.344V5.029V376.70W50.2°C229.5V
60% Load27.392A5.913A5.950A1.992A390.00W85.90%42.9°C0.962
12.055V5.073V3.327V5.020V454.00W52.3°C228.5V
80% Load36.831A7.925A8.016A2.415A520.00W84.83%45.2°C0.971
11.990V5.047V3.293V4.971V613.00W57.3°C227.4V
100% Load47.016A8.948A9.080A3.047A649.90W83.32%46.4°C0.979
11.917V5.029V3.271V4.922V780.00W61.3°C226.1V
Crossload 12.010A16.000A16.000A0.500A158.85W77.43%42.3°C0.924
12.204V4.993V3.243V5.096V205.15W50.4°C230.1V
Crossload 246.015A1.000A1.000A1.000A563.50W84.80%44.5°C0.973
11.952V5.118V3.366V5.047V664.50W56.2°C227.6V

Efficiency is decent for a Bronze unit that does not utilize DC-DC converters. Regarding voltage regulation at +12V it may be under 3% but we usually see below 2% readings on this rail. At 5V it is close to 2% and at 3.3V a little below 4%. In general 5V performed well here but the other two rails didn't break any performance records. As you can see from the full load test, although the unit is rated at 40°C, it had no problem delivering its full power at over 46°C.

Efficiency at Low Loads

In the next tests, we measure the efficiency of ZS 650W at loads much lower than 20% of its maximum rated load (the lowest load that the 80 Plus Standard measures). The loads that we dial are 40, 60, 80 and 100W (for PSUs with over 500W capacity). This is important for scenarios in which a typical office PC is in idle with power saving turned on.

Efficiency at Low Loads
OCZ ZS 650W
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyPF/AC
Volts
11.831A1.943A1.941A0.194A40.00W72.27%0.829
12.235V5.145V3.399V5.154V55.35W231.2V
23.384A1.943A1.942A0.390A60.00W77.97%0.866
12.235V5.145V3.397V5.127V76.95W231.0V
34.948A1.943A1.944A0.585A80.00W81.01%0.882
12.208V5.145V3.395V5.127V98.75W231.0V
46.504A1.943A1.945A0.784A100.00W82.95%0.893
12.208V5.145V3.393V5.100V120.55W231.3V

Efficiency at low loads is decent for a plain Bronze 650W unit, since we didn't see below 70% readings. With 80W and 100W load the unit managed to surpass the 80% mark, so it will provide significant energy savings in an average system at idle.

5VSB Efficiency

ATX spec states that the 5VSB standby supply's efficiency should be as high as possible and recommends 50% or higher efficiency with 100mA load, 60% or higher with 250mA load and 70% or higher with 1A or more load.
We will take four measurements, three at 100 / 250 / 1000 mA and one with the full load that 5VSB rail can handle.

5VSB Efficiency
OCZ ZS 650W
Test #5VSBPower (DC/AC)EfficiencyPF/AC Volts
10.100A0.52W47.27%0.073
5.154V1.10W233.1V
20.250A1.29W61.43%0.135
5.154V2.10W233.0V
31.000A5.10W71.53%0.322
5.100V7.13W232.1V
43.000A14.93W70.59%0.454
4.975V21.15W231.9V

Efficiency at 5VSB, with the only exception being test 1, is a little above the ATX recommended levels. With full load at 5VSB it would be ideal if efficiency was close to 80% rather than 70%.

Power Consumption in Idle & Standby

In the table below you will find the power consumption and the voltage values of all rails (except -12V), when the PSU is in idle mode (On but without any load at its rails) and the power consumption when the PSU is in standby (without any load at 5VSB).

Idle / Standby
OCZ ZS 650W
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.260V5.181V3.423V5.154V11.06W0.458
230.7V
Standby0.43 W0.029
232.3V

Vampire power is almost the same with the equivalent of ZS 750W. With only 0.43W the unit easily meets the ErP Lot 6 2010 requirements (and the future 2013 ones).
Next Page »Cross Load Tests
View as single page
Dec 22nd, 2024 00:15 EST change timezone

New Forum Posts

Popular Reviews

Controversial News Posts