Ripple Measurements
You will see the ripple levels we measured on the RM1000i's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Corsair RM1000i |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 5.2 mV | 7.1 mV | 7.5 mV | 5.5 mV | Pass |
---|
20% Load | 6.9 mV | 7.3 mV | 8.6 mV | 6.1 mV | Pass |
---|
30% Load | 7.5 mV | 7.8 mV | 8.5 mV | 6.6 mV | Pass |
---|
40% Load | 8.2 mV | 8.3 mV | 9.5 mV | 6.7 mV | Pass |
---|
50% Load | 8.8 mV | 9.4 mV | 10.1 mV | 8.0 mV | Pass |
---|
60% Load | 9.6 mV | 10.3 mV | 10.8 mV | 8.5 mV | Pass |
---|
70% Load | 10.9 mV | 11.5 mV | 12.6 mV | 9.8 mV | Pass |
---|
80% Load | 12.6 mV | 11.9 mV | 12.6 mV | 10.4 mV | Pass |
---|
90% Load | 14.7 mV | 13.3 mV | 14.8 mV | 10.7 mV | Pass |
---|
100% Load | 17.5 mV | 13.7 mV | 15.5 mV | 12.1 mV | Pass |
---|
110% Load | 23.8 mV | 14.0 mV | 16.8 mV | 13.6 mV | Pass |
---|
Crossload 1 | 7.0 mV | 7.5 mV | 7.2 mV | 7.4 mV | Pass |
---|
Crossload 2 | 17.6 mV | 13.8 mV | 16.5 mV | 11.6 mV | Pass |
---|
Ripple suppression was outstanding! Corsair and CWT did a great job here, which raises the bar in this category by a bunch. Taking into account the unit's performance in all the tests we conducted thus far, even the higher-classed Corsair HX1000i will have a hard time competing with it.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2