Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (15 A at +12V, 6 A at +5V, 6 A at +3.3V, and 0.5 A at 5VSB) is applied to the PSU for 20 ms while it is working at 20% load. In the second scenario, the PSU, while working at 50% load, is hit by the same transient load. For both tests, our oscilloscope measures the voltage drops caused by the transient load. All voltages should remain within the regulation limits defined by the ATX specification.

A PSU always operates under changing loads during real-world usage, depending on whether the CPU or graphics card is busy. It is of immense importance that the PSU can keep its rails within the limits defined by the ATX specification. Smaller deviations reduce the stress applied to other system components.

Note that the ATX specification requires capacitive loading during the transient tests. In our methodology, we chose to apply the worst-case scenario with no extra capacitance on the rails. Although the ATX specification asks for this capacitance, your system—the mainboard and its other parts—may not provide it, which we have to keep in mind.

Advanced Transient Response 20% - 50 Hz
VoltageBeforeAfterChangePass/Fail
12V12.124V11.945V1.48%Pass
5V5.049V4.952V1.92%Pass
3.3V3.304V3.222V2.49%Pass
5VSB5.081V5.047V0.67%Pass


Advanced Transient Response 50% - 50 Hz
VoltageBeforeAfterChangePass/Fail
12V12.089V12.004V0.70%Pass
5V5.041V4.950V1.81%Pass
3.3V3.298V3.213V2.57%Pass
5VSB5.059V5.028V0.61%Pass



The unit passed all normal transient tests with success. Since this is an ATX 3.0 PSU, I didn't expect anything less here.

Below are the oscilloscope screenshots we took during Advanced Transient Response testing.

Transient Response at 20% Load



Transient Response at 50% Load



ATX 3.0 Transient Tests

Below are the requirements of the ATX 3.0 standard, according to the PSU's capacity and whether it has a 12VHPWR connector or not.

Power Excursion % of PSU Rated Size
PSU <= 450 W and PSUs without 12VHPWR Connector
Power Excursion % of PSU Rated Size
PSU > 450 W and 12VHPWR Connector
Time for Power Excursion (Te)Testing Duty Cycle
150%200%100 ms5%
145%180%1 ms8%
135%160%10 ms12.5%
110%120%100 ms25%
100%100%Infinite--

The following table shows the applied loads, and the graphs depicting the results.

Duty CycleTime for Power Excursion (Te)Time Constant (Tc)Power @ TePower @ Tc
5%100 μs1900 μs1700 W780 W
8%1 ms11.5 ms1530 W762.7 W
12.5%10 ms70 ms1360 W749.3 W
25%100 ms300 ms1020 W785.2 W





The PSU passed all tests successfully, even with the extra capacitance the ATX 3.0 spec requires. Without any capacitance, which makes the tests even tougher, the PSU didn't have a problem at +12 V, which is noteworthy!

Turn-On Transient Tests

We measure the response of the PSU in more straightforward scenarios of transient load—during the power-on phase of the PSU—in the next set of tests. In the first test, we turn the PSU off, dial the maximum current the 5VSB can output, and then switch on the PSU. In the second test, we dial the maximum load +12V can handle and start the PSU while it's in standby mode. In the last test, while the PSU is completely switched off (we cut input power or switch the PSU off by flipping its on/off switch), we dial the maximum load the +12V rail can handle before switching the PSU on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for +12V is 13.2 V and 5.5 V for +5V).


Almost perfect results here.

Inrush Current

Inrush current, or switch-on surge, refers to the maximum, instantaneous input current drawn by an electrical device when it is first turned on. If high enough, inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays, and bridge rectifiers. As a result, the lower the inrush current of a PSU right as it is turned on, the better.


Inrush current is high with 230 V input.

Leakage Current

We use a GW Instek GPT-9904 electrical safety tester to measure the leakage current. According to the IEC-60950-1 regulation, no power supply should exceed 3.5 mA of leakage current, low enough not to harm anyone touching the chassis. This test is performed at 110% of the rated input voltage.


Leakage current is low.