Corsair CX Series Modular CX600M 600 W Review 19

Corsair CX Series Modular CX600M 600 W Review

Performance Rating & Performance per Dollar »

Ripple Measurements

You will see the ripple levels that we measured on the main rails of the CX600M in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements
Corsair CX600M
Test12 V5 V3.3 V5VSBPass/Fail
20% Load12.2 mV8.2 mV9.4 mV9.9 mVPass
40% Load15.5 mV8.6 mV10.4 mV11.7 mVPass
50% Load17.0 mV10.1 mV11.3 mV13.0 mVPass
60% Load20.0 mV10.7 mV12.2 mV14.2 mVPass
80% Load28.7 mV11.7 mV14.3 mV16.8 mVPass
100% Load41.2 mV13.9 mV20.1 mV23.5 mVPass
110% Load59.1 mV18.6 mV26.5 mV30.4 mVPass
Crossload 112.9 mV20.1 mV10.9 mV9.7 mVPass
Crossload 253.1 mV20.5 mV22.9 mV25.9 mVPass

Overall Ripple suppression is very good despite the highly stressful conditions in which we conducted all of our tests. The Corsair CX600M proved that it can easily operate at temperatures that exceed 40°C while delivering very clean outputs throughout the entire load range.

Ripple at Full Load

In the following oscilloscope screenshots, you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V, and 5VSB). The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. For all measurements, we set 0.01 V/Div (each vertical division/box equals 0.01 V) as standard.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating & Performance per Dollar
View as single page
Jul 30th, 2024 18:15 EDT change timezone