Fractal Design Tesla R2 1000 W Review 3

Fractal Design Tesla R2 1000 W Review

Ripple Measurements »

Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (10 A at +12V, 5 A at 5V, 5 A at 3.3V, and 0.5 A at 5VSB) is applied to the PSU for 200 ms while the latter is working at a 20% load state. The PSU is, while working at 50% load, hit by the same transient load in the second scenario. In both tests, we measure the voltage drops that the transient load causes using our oscilloscope. The voltages should remain within the regulation limits defined by the ATX specification. We must stress here that the above tests are crucial since they simulate transient loads that a PSU is very likely to handle (e.g., booting a RAID array, an instant 100% load of CPU/VGAs, etc.). We call these tests "Advanced Transient Response Tests", and they are designed to be very tough to master, especially for PSUs with capacities lower than 500 W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V12.113V12.016V0.80%Pass
5 V5.027V4.876V3.00%Pass
3.3 V3.384V3.249V3.99%Pass
5VSB5.085V5.052V0.65%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V12.068V11.964V0.86%Pass
5 V5.012V4.875V2.73%Pass
3.3 V3.357V3.232V3.72%Pass
5VSB5.048V5.003V0.89%Pass


The performance of the +12V rail was very good in these tests, since the deviation was under 1% in both. Deviations on the minor rails were good enough with 3.3V registering the highest one, but the same rail didn't drop its voltage very low in any of the tests. It even managed to register readings of over 3.2 V on both tests.

You will find the oscilloscope screenshots that we took during our Advanced Transient Response Tests below.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

We measure the response of the PSU in simpler scenarios of transient loads—during the power-on phase of the PSU—in the next set of tests. In the first test, we turn the PSU off, dial the maximum current that the 5VSB can output, and then switch on the PSU. In the second test, we dial the maximum load that +12V can handle and start the PSU while the PSU is in standby mode. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's on/off switch), we dial the maximum load that the +12V rail can handle before switching the PSU on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for 12V is 13.2V and 5.5V for 5V).


We measured a small spike at 5VSB, but it is nothing to worry about. The slope of the second test is almost perfect, but the last one registered some ups and downs before settling down. The PSU's overall performance was good enough in these tests.
Next Page »Ripple Measurements