Kolink Enclave Series 700 W Review 11

Kolink Enclave Series 700 W Review

Performance Rating, Noise & Efficiency Rating »

Protection Features Evaluation

Protection Features
OCP12V: 77.8 A (134.14%), 12.101 V
5V: 22.6 A (141.25%), 4.951 V
3.3V: 23.7 A (148.13%), 3.345 V
5VSB: 3.7 A (123.33%), 5.037 V
OPP946.9 W (135.27%)
OTPYes (119 °C @ 12 V heat sink)
SCP12V: Yes
5V: Yes
3.3V: Yes
5VSB: Yes
-12V: Yes
PWR_OKProper Operation
NLOYes
SIPSurge: MOV
Inrush: NTC & Bypass Relay

DC Power Sequencing

According to Intel's most recent Power Supply Design Guide (revision 1.4), the +12V and 5V rails must have voltages equal or greater than the 3.3V rail's output at all times—during start up and regular operation. For our first measurement, we turn the unit off and switch it back on without any load on any of the rails.



EMC Pre-Compliance Testing – Average and Peak EMI Detector Results

Electromagnetic Compatibility (EMC) is the ability of a device to operate properly in its environment without disrupting the proper operation of other close-by devices.

Electromagnetic Interference (EMI) stands for the electromagnetic energy a device emits, and it can cause problems in other close-by devices if too high.



There are some spurs at the lower frequencies, one of which goes over the limit with the average EMI detector active.
Next Page »Performance Rating, Noise & Efficiency Rating
View as single page
Jul 24th, 2024 05:29 EDT change timezone