Ripple Measurements
You will see the ripple levels that we measured on the main rails of the MK3S750 in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements PC Power & Cooling MK3S750 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
20% Load | 12.7 mV | 8.3 mV | 8.5 mV | 3.9 mV | Pass |
40% Load | 18.6 mV | 8.2 mV | 9.3 mV | 4.5 mV | Pass |
50% Load | 21.1 mV | 9.2 mV | 10.7 mV | 5.2 mV | Pass |
60% Load | 24.0 mV | 9.4 mV | 12.3 mV | 6.2 mV | Pass |
80% Load | 30.1 mV | 10.5 mV | 14.7 mV | 7.1 mV | Pass |
100% Load | 35.9 mV | 10.6 mV | 18.2 mV | 9.8 mV | Pass |
110% Load | 40.1 mV | 10.9 mV | 18.8 mV | 10.0 mV | Pass |
Crossload 1 | 16.3 mV | 11.1 mV | 12.9 mV | 4.1 mV | Pass |
Crossload 2 | 34.6 mV | 11.0 mV | 14.6 mV | 6.1 mV | Pass |
Ripple suppression is very good and is especially great on the minor rails! Super Flower did an excellent job with this platform, and the PSU managed to deliver ultra-clean outputs despite the tough conditions we conducted all of our tests in.
Ripple at Full Load
In the following oscilloscope screenshots, you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V, and 5VSB). The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. For all measurements, we set 0.01 V/Div (each vertical division/box equals 0.01 V) as standard.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2