Seasonic Focus SPX Series 750 W SFX PSU Review 28

Seasonic Focus SPX Series 750 W SFX PSU Review

Transient Response, Inrush & Leakage Current »

Hold-Up Time

Hold-up time represents the duration for which a PSU can maintain stable output as defined by the ATX specification without input power. This is very important when the quality of your electricity varies, and there are short drops in the supply (dips or brownouts).

In the oscilloscope screenshots below, the blue line is the AC input mains signal, the green line the "Power Good" signal, and the yellow line the +12V rail. The measured timing variable is listed as ΔX.

Hold-Up Time





AC Loss to PWR_OK Hold-Up Time





PWR_OK Inactive to DC Loss Delay





Hold-up time is below 17 ms. The power ok signal is accurate but short.

Timings for Alternative Low Power Modes (ALPM)

Traditionally, sleep mode (S3) shuts the system off for a long time (minutes or hours) to reduce power consumption. However, this approach adds a few seconds of delay when resuming from standby. Microsoft recently introduced Modern Standby, which brings the instant-on capability to PCs—just like your phone instantly turns on without any noticeable delay. Modern Standby builds on the Alternative Low Power Modes capability, which Intel has defined. To support ALPM, a power supply must wake up from sleep quickly to ensure system stability—think of it as the PSU's boot time.

For the reviewed PSU, we measured T1 and T3 at 20% and 100% load.

T1 (Power-on time) & T3 (PWR_OK delay)
LoadT1T3
20%69 ms133 ms
100%69 ms133 ms


Power-on time is below 100 ms, which is good. The PWR_OK delay is below 150 ms, so the PSU supports Alternative Low Power Mode.
Next Page »Transient Response, Inrush & Leakage Current
View as single page
Aug 17th, 2024 15:19 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts