Ripple Measurements
In the following table you will find the ripple levels that we measured on the main rails of HCG-620M. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V, 3.3V and 5VSB).
Ripple Measurements Antec HCG-620M |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
20% Load | 3.9 mV | 4.7 mV | 7.7 mV | 8.4 mV | Pass |
40% Load | 4.4 mV | 4.8 mV | 8.0 mV | 8.8 mV | Pass |
50% Load | 6.0 mV | 5.2 mV | 8.8 mV | 10.0 mV | Pass |
60% Load | 7.3 mV | 6.8 mV | 10.3 mV | 11.8 mV | Pass |
80% Load | 9.2 mV | 7.9 mV | 16.0 mV | 12.7 mV | Pass |
100% Load | 13.3 mV | 8.5 mV | 20.3 mV | 15.4 mV | Pass |
Crossload 1 | 8.2 mV | 24.2 mV | 7.7 mV | 6.4 mV | Pass |
Crossload 2 | 12.9 mV | 6.1 mV | 20.9 mV | 13.5 mV | Pass |
Ripple at Full Load
In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V and 5VSB). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. For all measurements we set 0.01 V/Div (each vertical division/box equals to 0.01V) as standard.
Ripple at Crossload 1
Ripple at Crossload 2