Advanced Transient Response Tests

In these tests we monitor the response of the PSU in two different scenarios. First a transient load (11A at +12V, 5A at 5V, 6A at 3.3V and 0.5A at 5VSB) is applied for 50 ms to the PSU, while the latter is working at a 20% load state. In the second scenario the PSU, while working with 50% load, is hit by the same transient load. In both tests, we measure the voltage drops that the transient load causes, using our oscilloscope. In any case voltages should remain within the regulation limits specified by the ATX specification. We must stress here, that the above tests are crucial, since they simulate transient loads that a PSU is very likely to handle (e.g. starting of a RAID array, an instant 100% load of CPU/VGAs etc.) We call these tests “Advanced Transient Response Tests” and they are designed to be very tough to master, especially for PSUs with capacities lower than 500W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V12.107V11.915V1.59%Pass
5 V5.020V4.895V2.49%Pass
3.3 V3.341V3.213V3.83%Pass
5VSB5.064V5.022V0.83%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V12.055V11.877V1.48%Pass
5 V4.984V4.854V2.61%Pass
3.3 V3.302V3.138V4.97%Pass
5VSB5.038V4.946V2.34%Pass


Regardless the fact that low capacity poses a big handicap in these tests, the VP550P managed to keep all of its rails within ATX spec voltage regulation limits on all tests. The worst performer was the 3.3V rail which, in the second test registered the highest voltage drop and was only a hair away from the limit. What we didn't like here were the voltage overshoots we measured on all rails besides 5VSB.

Below you will find the oscilloscope screenshots that we took during Advanced Transient Response Testing.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

In the next set of tests we measure the response of the PSU in simpler scenarios of transient loads, during the turn on phase of the PSU. In the first test we turn off the PSU, dial 2A load at 5VSB and then switch on the PSU. In the second test, while the PSU is in standby, we dial the maximum load that +12V can handle and we start the PSU. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's On/Off switch), we dial the maximum load that +12V can handle and then we switch on the PSU from the loader and we restore power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g. +10% for 12V is 13.2V and for 5V is 5.5V).


The performance in these tests is almost flawless since the only thing we noticed was a small wave in the waveform of the second test. However this is nothing to lose sleep over.