PC Power & Cooling Silencer MK III 1200 W Review 7

PC Power & Cooling Silencer MK III 1200 W Review

Ripple Measurements »

Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (11 A at +12V, 5 A at 5V, 6 A at 3.3V, and 0.5 A at 5VSB) is applied to the PSU for 50 ms with the latter working at a 20% load state. In the second scenario, the PSU, while working at 50% load, is hit by the same transient load. In both tests, we measure the voltage drops that the transient load causes, using our oscilloscope. In any case, the voltages should remain within the regulation limits defined by the ATX specification. We must stress here that the above tests are crucial, since they simulate transient loads that a PSU is very likely to handle (e.g., booting a RAID array, an instant 100% load of CPU/VGAs, etc.) We call these tests "Advanced Transient Response Tests" and they are designed to be very tough to master, especially for PSUs with capacities lower than 500 W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V12.187V12.084V0.85%Pass
5 V5.118V4.898V4.30%Pass
3.3 V3.348V3.235V3.38%Pass
5VSB5.082V5.017V1.28%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V12.097V11.989V0.89%Pass
5 V5.064V4.869V3.85%Pass
3.3 V3.293V3.180V3.43%Pass
5VSB5.029V4.965V1.27%Pass


The +12V rail registers small deviations below 1%, on both tests. This isn't the case for 5V which shows the worst performance among all rails here with deviations remaining under 5%. Its voltage reading during the transient load is near the nominal one, thanks to the initial high reading. The 3.3V and 5VSB rails performed fairly well here.

Below you will find the oscilloscope screenshots that we took during Advanced Transient Response Testing.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

In the next set of tests, we measure the response of the PSU in simpler scenarios of transient loads during the power-on phase of the PSU. In the first test, we turn off the PSU, dial 2 A of load at 5VSB and then switch on the PSU. In the second test, while the PSU is in standby mode, we dial the maximum load that +12V can handle and we start the PSU. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's on/off switch), we dial the maximum load that the +12V rail can handle and switch on the PSU on from the loader before restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for 12V is 13.2V and for 5V is 5.5V).


Absolutely excellent performance. No spikes or voltage overshoots in any of the three tests with rise time constantly between the 0.2 - 20ms range. There is simply nothing more to ask for.
Next Page »Ripple Measurements
View as single page