Seasonic Connect 750 W Review - The Solution for Cable Management 15

Seasonic Connect 750 W Review - The Solution for Cable Management

Fan Noise »

Efficiency

Using the results we gathered so far, we plotted a chart showing the PSU's efficiency at low loads and loads ranging from 10 to 110 percent of the maximum-rated capacity.




Not the most efficient design, especially with 2% load. However, you cannot call it bad either. It is just that the competition is fierce.

10%–110% Load Testing

These tests reveal the PSU's load regulation and efficiency levels under high ambient temperatures. They also show how the fan speed profile behaves under tough operating conditions.

Load Regulation & Efficiency Testing Data - Seasonic SSR-750FA
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
10% Load4.425A1.988A1.981A0.983A74.961W86.357%0 RPM<6.0 dB(A)45.19°C0.822
12.059V5.030V3.331V5.089V86.804W40.19°C230.35V
20% Load9.881A2.985A2.976A1.184A150.036W90.386%570 RPM18.9 dB(A)41.05°C0.913
12.056V5.027V3.327V5.071V165.994W46.34°C230.34V
30% Load15.679A3.485A3.474A1.386A225.041W91.592%554 RPM18.3 dB(A)41.90°C0.944
12.053V5.024V3.325V5.052V245.700W47.76°C230.34V
40% Load21.478A3.984A3.974A1.590A300.052W91.947%685 RPM22.4 dB(A)42.41°C0.959
12.051V5.022V3.324V5.034V326.333W48.60°C230.34V
50% Load26.901A4.982A4.970A1.795A374.606W91.882%890 RPM29.7 dB(A)42.59°C0.967
12.048V5.018V3.320V5.015V407.702W49.50°C230.34V
60% Load32.358A5.986A5.971A2.000A449.537W91.573%1172 RPM38.4 dB(A)43.00°C0.973
12.044V5.015V3.317V4.996V490.905W50.81°C230.33V
70% Load37.851A6.987A6.974A2.211A524.882W91.190%1355 RPM40.5 dB(A)43.17°C0.976
12.041V5.011V3.313V4.976V575.589W51.39°C230.31V
80% Load43.345A7.991A7.975A2.422A600.199W90.693%1733 RPM47.4 dB(A)43.32°C0.979
12.038V5.007V3.310V4.956V661.793W52.33°C230.31V
90% Load49.205A8.495A8.464A2.429A674.701W90.272%1927 RPM50.5 dB(A)44.44°C0.981
12.035V5.005V3.308V4.941V747.406W54.19°C230.31V
100% Load54.873A8.998A8.984A3.055A749.944W89.762%1942 RPM51.1 dB(A)45.64°C0.982
12.032V5.002V3.306V4.911V835.478W55.81°C230.30V
110% Load61.135A9.000A8.986A3.065A825.169W89.306%1949 RPM51.5 dB(A)46.63°C0.983
12.030V5.001V3.305V4.896V923.979W57.44°C230.30V
Crossload 10.117A12.000A11.998A0.000A101.063W85.200%615 RPM20.3 dB(A)42.82°C0.873
12.048V5.006V3.299V5.096V118.619W49.01°C230.35V
Crossload 262.015A1.000A0.999A1.000A760.046W90.406%1942 RPM51.1 dB(A)45.24°C0.982
12.041V5.023V3.333V4.970V840.705W55.97°C230.30V

I noticed that the PF readings are not that high, especially at high loads. The PFC converter needs a little tuning to better match the voltage and current waveforms.

Light Load Testing

In the following tests, we measure the PSU's efficiency at loads significantly lower than 10 percent of the maximum capacity (the lowest load the 80 PLUS standard measures). This is important for representing when a PC is idle with its power-saving features turned on.

Efficiency at Low Loads - Seasonic SSR-750FA
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
12.892A0.497A0.493A0.196A40.019W80.125%0 RPM<6.0 dB(A)0.689
12.057V5.036V3.337V5.113V49.946W230.25V
24.118A0.995A0.991A0.392A59.968W84.692%0 RPM<6.0 dB(A)0.775
12.058V5.033V3.334V5.105V70.807W230.26V
35.353A1.490A1.485A0.589A79.986W87.140%0 RPM<6.0 dB(A)0.829
12.057V5.030V3.332V5.097V91.790W230.26V
46.586A1.988A1.983A0.786A100.022W88.692%0 RPM<6.0 dB(A)0.863
12.059V5.029V3.330V5.090V112.775W230.27V

At light loads, efficiency levels are satisfactory, and the fan does not spin, which means noise output is minimal.

Ultra-light Load Testing

The applied load in this test is only 10 W for PSUs with 500 W and less capacity. We dial in 2% of the maximum-rated capacity for all other PSUs. We only run this test with 115 V input.

Efficiency at Low Loads - Seasonic SSR-750FA
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
11.080A0.209A0.211A0.052A15.043W61.248%0 RPM<6.0 dB(A)0.824
12.056V5.037V3.338V5.118V24.561W115.15V

It would be nice to see over 70% efficiency with 2% load.

5VSB Efficiency

5VSB Efficiency - Seasonic SSR-750FA
Test #5VSBPower (DC/AC)EfficiencyPF/AC Volts
10.100A0.512W68.725%0.037
5.121V0.745W230.33V
20.250A1.279W71.935%0.084
5.116V1.778W230.33V
30.550A2.811W75.626%0.160
5.109V3.717W230.33V
41.000A5.100W76.199%0.243
5.098V6.693W230.33V
51.500A7.632W76.312%0.300
5.087V10.001W230.33V
63.000A15.153W76.069%0.380
5.051V19.920W230.33V


The 5VSB circuit needs an upgrade for the sake of better efficiency.

Power Consumption in Idle and Standby

Idle / Standby - Seasonic SSR-750FA
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.056V5.037V3.337V5.121V9.596W0.297
230.3V
Standby0.069W0.003
230.3V

Vampire power is low.
Next Page »Fan Noise
View as single page
Dec 23rd, 2024 05:20 EST change timezone

New Forum Posts

Popular Reviews