Cross Load Tests
For the generation of the following charts, we set our loaders to auto mode through our custom-made software before trying over a thousand possible load combinations with the +12V, 5V, and 3.3V rails. The voltage regulation deviations in each of the charts below were calculated by taking the nominal values of the rails (12V, 5V, and 3.3V) as point zero. We should note here that we usually conduct this test with PSUs that have a capacity equal to or lower than 1000 W since it takes a long time to run and because its completion time increases exponentially as the capacity of a unit increases. However, we made an exception since this unit's platform is used by several well-known vendors (e.g. Antec and EVGA) - we were very curious about its performance on these tests throughout its entire operational range.
+12V Voltage Regulation Chart
5V Voltage Regulation Chart
3.3V Voltage Regulation Chart
Efficiency Chart
+12V Ripple Chart
5V Ripple Chart
3.3V Ripple Chart
5VSB Ripple Chart