Apexgaming AG-850M Review 13

Apexgaming AG-850M Review

Protection Features Evaluation »

Ripple Measurements

You will see the ripple levels we measured on the rails of the AG-850M in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Apexgaming AG-850M
Test12 V5 V3.3 V5VSBPass/Fail
10% Load12.2 mV13.4 mV12.9 mV5.3 mVPass
20% Load14.7 mV15.6 mV15.2 mV6.0 mVPass
30% Load18.3 mV16.7 mV16.8 mV6.7 mVPass
40% Load21.7 mV18.2 mV18.7 mV8.1 mVPass
50% Load24.5 mV20.6 mV21.1 mV8.5 mVPass
60% Load27.7 mV22.1 mV23.3 mV9.3 mVPass
70% Load31.0 mV23.7 mV25.6 mV10.4 mVPass
80% Load34.7 mV27.1 mV29.2 mV11.3 mVPass
90% Load41.0 mV29.2 mV31.2 mV11.9 mVPass
100% Load45.0 mV31.7 mV34.6 mV14.5 mVPass
110% Load52.7 mV34.6 mV37.3 mV15.1 mVPass
Crossload 116.2 mV29.3 mV30.3 mV12.6 mVPass
Crossload 244.8 mV24.8 mV29.4 mV13.5 mVPass

Ripple suppression might not be up to Super Flower or Seasonic standards, but is still good enough overall.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2