Ripple Measurements
You will see the ripple levels we measured on the rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V), and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Cooler Master V550 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 9.3 mV | 4.5 mV | 13.9 mV | 3.9 mV | Pass |
---|
20% Load | 9.3 mV | 5.1 mV | 15.5 mV | 4.2 mV | Pass |
---|
30% Load | 10.4 mV | 4.9 mV | 16.5 mV | 4.9 mV | Pass |
---|
40% Load | 12.1 mV | 5.4 mV | 18.4 mV | 5.2 mV | Pass |
---|
50% Load | 14.3 mV | 5.9 mV | 18.8 mV | 5.5 mV | Pass |
---|
60% Load | 16.4 mV | 6.1 mV | 19.1 mV | 6.1 mV | Pass |
---|
70% Load | 18.7 mV | 6.4 mV | 20.9 mV | 6.9 mV | Pass |
---|
80% Load | 20.3 mV | 6.6 mV | 22.4 mV | 7.3 mV | Pass |
---|
90% Load | 21.9 mV | 7.2 mV | 22.8 mV | 7.6 mV | Pass |
---|
100% Load | 24.7 mV | 7.8 mV | 25.6 mV | 11.4 mV | Pass |
---|
110% Load | 27.0 mV | 8.3 mV | 26.4 mV | 9.2 mV | Pass |
---|
Crossload 1 | 11.9 mV | 5.8 mV | 17.9 mV | 4.7 mV | Pass |
---|
Crossload 2 | 25.1 mV | 8.0 mV | 24.4 mV | 7.7 mV | Pass |
---|
Ripple suppression at +12V, 5V and 5VSB was great and good-enough at 3.3V. Although it didn't do poorly, the 3.3V rail is this PSU's weak link considering its average overall performance.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2