Corsair AXi Series 1600 W Review 13

Corsair AXi Series 1600 W Review

Protection Features Evaluation »

Ripple Measurements

You will see the ripple levels we measured on the rails of the Corsair AX1600i in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Corsair AX1600i -230V
Test12 V5 V3.3 V5VSBPass/Fail
10% Load5.6 mV3.2 mV6.8 mV2.7 mVPass
20% Load7.0 mV3.5 mV6.9 mV2.8 mVPass
30% Load7.3 mV3.4 mV6.5 mV2.9 mVPass
40% Load8.0 mV3.6 mV6.3 mV3.0 mVPass
50% Load8.4 mV4.0 mV6.5 mV2.9 mVPass
60% Load8.1 mV3.7 mV6.7 mV2.9 mVPass
70% Load8.3 mV4.3 mV6.9 mV3.1 mVPass
80% Load8.3 mV4.7 mV7.3 mV3.3 mVPass
90% Load8.9 mV5.4 mV7.5 mV3.6 mVPass
100% Load10.2 mV5.7 mV8.4 mV4.0 mVPass
110% Load11.5 mV4.7 mV7.6 mV3.3 mVPass
Crossload 15.4 mV5.8 mV6.8 mV2.8 mVPass
Crossload 210.6 mV4.2 mV7.4 mV3.3 mVPass
Ripple suppression is jaw-dropping! The digital control and number of filtering caps, and extra caps on some of the cables, are the reasons for such a magnificent result!

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Protection Features Evaluation
View as single page
Jul 20th, 2024 07:22 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts