Enermax Platimax 1500 W Review 17

Enermax Platimax 1500 W Review

Performance Rating & Performance per Dollar »

Ripple Measurements

In the following table you will find the ripple levels that we measured on the main rails of EPM1500EGT. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V, 3.3V and 5VSB).

Ripple Measurements
Enermax EPM1500EGT
Test12 V5 V3.3 V5VSBPass/Fail
20% Load15.3 mV18.4 mV13.6 mV12.4 mVPass
40% Load19.7 mV23.4 mV15.8 mV17.0 mVPass
50% Load23.5 mV26.3 mV18.0 mV20.2 mVPass
60% Load24.5 mV28.4 mV18.4 mV20.3 mVPass
80% Load26.6 mV33.5 mV23.0 mV26.6 mVPass
100% Load29.7 mV36.4 mV24.8 mV31.3 mVPass
Crossload 135.9 mV47.6 mV23.9 mV13.0 mVPass
Crossload 217.0 mV22.8 mV18.6 mV26.3 mVPass

Ripple suppression at +12V is excellent! Even at full load (1500W) it doesn't exceed 30mV and this is what we call ground breaking performance. However the most impressive part is at CL2 test where +12V alone deliver 1500W and ripple on the same rail is constrained to below 20mV. Regarding the other rails, at 3.3V and 5VSB ripple suppression is good enough while at 5V it is mediocre, especially for a high-end unit.

Ripple at Full Load

In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V and 5VSB). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. For all measurements we set 0.01 V/Div (each vertical division/box equals to 0.01V) as standard.



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating & Performance per Dollar