Ripple Measurements

Below you will find the ripple levels that we measured on the main rails of AX600-88FE. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V & 3.3V).

Ripple Measurements
Test12 V5 V3.3 VPass/Fail
20% Load30.6 mV23.6 mV23.2 mVPass
40% Load39.6 mV26.0 mV27.4 mVPass
50% Load36.8 mV23.2 mV26.0 mVPass
60% Load40.4 mV21.8 mV27.2 mVPass
80% Load48.4 mV27.2 mV32.8 mVPass
100% Load53.6 mV22.8 mV31.2 mVPass
Crossload 126.8 mV24.2 mV31.4 mVPass
Crossload 261.2 mV28.4 mV34.6 mVPass

Ripple-noise suppression is good but not among the best we have seen (the latter mainly goes for the minor rails).

Ripple at Full Load

In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals to 0.01V) as standard but sometimes we are forced to use 0.02 V/Div, meaning that the fluctuations will look smaller but actually this wont be the case.



Ripple at Crossload 2

For the first screenshot we used 0.02 V/Div, so actually the registered ripple is much bigger than it seems (compared to the other screenshots where 0.01 V/Div was used). As above the order of images is +12V, 5V and 3.3V.