Corsair AX1200i 1200 W Review 13

Corsair AX1200i 1200 W Review

Ripple Measurements »

Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (11 A at +12V, 5 A at 5V, 6 A at 3.3V, and 0.5 A at 5VSB) is applied to the PSU for 50 ms, while the latter is working at a 20% load state. In the second scenario, the PSU, while working at 50% load, is hit by the same transient load. In both tests, we measure the voltage-drops that the transient load causes using our oscilloscope. The voltages should, in any case, remain within the regulation limits defined by the ATX specification. We must stress here that the above tests are crucial, since they simulate transient loads that a PSU is very likely to handle (e.g., booting a RAID array, an instant 100% load of CPU/VGAs, etc.) We call these tests "Advanced Transient Response Tests" and they are designed to be very tough to master, especially for PSUs with capacities lower than 500 W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V11.979V11.853V1.05%Pass
5 V4.957V4.872V1.71%Pass
3.3 V3.284V3.196V2.68%Pass
5VSB5.011V4.948V1.26%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V11.955V11.847V0.90%Pass
5 V4.922V4.836V1.75%Pass
3.3 V3.253V3.166V2.67%Pass
5VSB4.975V4.910V1.31%Pass


The registered deviations of all rails during these tests remained at low levels and didn't exceed 3%. However, the somehow low voltage of the 3.3V rail, before the application of the transient load, led to an under 3.2V reading during the transient load. Nevertheless, the specific rail's voltage still remained at a safe distance from the low limit that the ATX spec specifies for this rail.


Below you will find the oscilloscope screenshots that we took during Advanced Transient Response Testing.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

In the next set of tests, we measure the response of the PSU in simpler scenarios of transient loads during the power-on phase of the PSU. In the first test, we turn off the PSU, dial 2 A of load at 5VSB and then switch on the PSU. In the second test, while the PSU is in standby mode, we dial the maximum load that +12V can handle and we start the PSU. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's on/off switch), we dial the maximum load that the +12V rail can handle, then we switch on the PSU from the loader and we restore power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for 12V is 13.2V and for 5V is 5.5V).


In all three tests we measured a small voltage overshoot, which, on the 5VSB rail, didn't exceed the nominal voltage while, on the +12V rail, it barely surpassed it. All in all, the performance of the unit in these tests was very good.
Next Page »Ripple Measurements
View as single page
Jul 18th, 2024 09:29 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts