Ripple Measurements
You will see the ripple levels we measured on the HX750i's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Corsair HX750i |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 11.0 mV | 4.0 mV | 13.1 mV | 3.0 mV | Pass |
---|
20% Load | 12.6 mV | 4.3 mV | 12.6 mV | 3.4 mV | Pass |
---|
30% Load | 14.1 mV | 4.5 mV | 13.1 mV | 3.4 mV | Pass |
---|
40% Load | 13.7 mV | 8.0 mV | 25.2 mV | 7.1 mV | Pass |
---|
50% Load | 14.9 mV | 5.0 mV | 15.0 mV | 4.6 mV | Pass |
---|
60% Load | 15.9 mV | 5.0 mV | 15.1 mV | 5.2 mV | Pass |
---|
70% Load | 17.2 mV | 6.0 mV | 17.0 mV | 5.8 mV | Pass |
---|
80% Load | 19.1 mV | 6.4 mV | 17.4 mV | 7.6 mV | Pass |
---|
90% Load | 21.1 mV | 6.7 mV | 19.4 mV | 6.8 mV | Pass |
---|
100% Load | 22.8 mV | 7.7 mV | 19.5 mV | 7.6 mV | Pass |
---|
110% Load | 25.1 mV | 7.8 mV | 19.9 mV | 8.0 mV | Pass |
---|
Crossload 1 | 17.0 mV | 6.7 mV | 14.9 mV | 5.2 mV | Pass |
---|
Crossload 2 | 22.2 mV | 6.8 mV | 18.8 mV | 7.2 mV | Pass |
---|
Ripple suppression was excellent on all rails, with 5V and 5VSB providing near-perfect DC outputs. Even our 110% load test with extremely tough operating conditions couldn't make the HX750i break a sweat. On the contrary, its main rail, +12V, only had close to 25 mV ripple, a performance level only incredibly well-designed platforms exhibit. CWT's engineers did a hell of a job with this platform, and we can easily state that they matched Delta's and Super Flower's performance in this department.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2