Cougar PowerX 550 W Review 0

Cougar PowerX 550 W Review

Ripple Measurements »

Advanced Transient Response Tests

In these tests, we monitor the response of the PSU in two different scenarios. First, a transient load (10 A at +12V, 5 A at 5V, 5 A at 3.3V, and 0.5 A at 5VSB) is applied to the PSU for 200 ms while the latter is working at a 20% load state. In the second scenario, the PSU, while working at 50% load, is hit by the same transient load. In both tests, we measure the voltage drops that the transient load causes using our oscilloscope. The voltages should remain within the regulation limits defined by the ATX specification. We must stress here that the above tests are crucial since they simulate transient loads that a PSU is very likely to handle (e.g., booting a RAID array, an instant 100% load of CPU/VGAs, etc.) We call these tests "Advanced Transient Response Tests", and they are designed to be very tough to master, especially for PSUs with capacities lower than 500 W.

Advanced Transient Response 20%
VoltageBeforeAfterChangePass/Fail
12 V12.086V11.876V1.74%Pass
5 V5.074V4.962V2.21%Pass
3.3 V3.305V3.187V3.57%Pass
5VSB4.979V4.934V0.90%Pass


Advanced Transient Response 50%
VoltageBeforeAfterChangePass/Fail
12 V12.034V11.822V1.76%Pass
5 V5.045V4.947V1.94%Pass
3.3 V3.280V3.112V5.12%Fail
5VSB4.938V4.867V1.44%Pass


The responses of the +12V, 5V, and 5VSB rails to dynamic loads were good enough, but both cases at 3.3V measured readings below 3.2 V, and the same rail failed to keep its voltage within the ATX specified range during the second test. As it seems, some manufacturers don't pay much attention to the design of the circuits that regulate the minor rails, since they are lightly used nowadays, but such design results in a far from optimal response on those rails.


Below, you will find the oscilloscope screenshots that we took during Advanced Transient Response Testing.

Transient Response at 20% Load



Transient Response at 50% Load



Turn-On Transient Tests

We measure the response of the PSU in simpler scenarios of transient loads—during the power-on phase of the PSU—in the next set of tests. In the first test, we turn the PSU off, dial the maximum current that the 5VSB can output, and then switch on the PSU. In the second test, we dial the maximum load that +12V can handle and start the PSU while the PSU is in standby mode. In the last test, while the PSU is completely switched off (we cut off power or switch off the PSU's on/off switch), we dial the maximum load that the +12V rail can handle before switching the PSU on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10% of their nominal values (e.g., +10% for 12V is 13.2V and for 5V is 5.5V).


We didn't measure any noticeable spikes or voltage overshoots during these tests; however, the slope on the last test was far from smooth; it registered a significant dive at around 3.6 V, but such a spike won't endanger any system components, so you don't have to lose sleep over it, especially considering that this is also highly unlikely to happen in a real-life situation.
Next Page »Ripple Measurements