Sama Forza Titanium 800 W Review 34

Sama Forza Titanium 800 W Review

EMC Pre-Compliance Testing »

Ripple Measurements

You will see the ripple levels we measured on the FTX-800-2's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - SAMA FTX-800-2
Test12 V5 V3.3 V5VSBPass/Fail
10% Load18.8 mV10.1 mV12.1 mV7.1 mVPass
20% Load17.0 mV11.4 mV13.2 mV8.3 mVPass
30% Load24.0 mV12.6 mV14.6 mV9.8 mVPass
40% Load24.1 mV13.9 mV15.9 mV11.5 mVPass
50% Load25.6 mV14.6 mV17.4 mV12.3 mVPass
60% Load29.1 mV19.9 mV20.4 mV16.5 mVPass
70% Load31.1 mV20.9 mV22.7 mV17.8 mVPass
80% Load33.2 mV18.6 mV24.9 mV17.0 mVPass
90% Load35.6 mV20.0 mV25.8 mV18.5 mVPass
100% Load41.1 mV23.0 mV28.6 mV20.7 mVPass
110% Load42.1 mV23.1 mV28.9 mV21.1 mVPass
Crossload 121.0 mV17.0 mV23.5 mV10.1 mVPass
Crossload 238.0 mV17.6 mV20.9 mV18.1 mVPass
Overall ripple suppression is good. While it is no match to Super Flower's implementations, this PSU will produce clean outputs under even extremely hard conditions.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »EMC Pre-Compliance Testing
View as single page
Dec 25th, 2024 20:09 EST change timezone

New Forum Posts

Popular Reviews

Controversial News Posts