All measurements were performed using two Chroma 6314A mainframes equipped with the following electronic loads: six 63123A [350 W each], one 63102A [100 W x2], and one 63101A [200 W]. The aforementioned equipment is able to deliver 2500 W of load, and all loads are controlled by a custom-made software. We also used a Rigol DS2072A oscilloscope kindly sponsored by Batronix, a Picoscope 3424 oscilloscope, a Picotech TC-08 thermocouple data logger, two Fluke multimeters (models 289 and 175), and a Yokogawa WT210 power meter. We also included a wooden box, which, along with some heating elements, was used as a hot box. Finally, we had at our disposal three more oscilloscopes (Rigol VS5042, Stingray DS1M12, and a second Picoscope 3424), and a CEM DT-8852 sound level meter. You will find more details about our equipment and the review methodology we follow in this article. We conduct all of our tests at 40°C-45°C ambient to simulate the environment seen inside a typical system with a higher accuracy, with 40°C-45°C being derived from a standard ambient assumption of 23°C and 17°C-22°C being added for the typical temperature rise within a system.

Rigol DS2072A kindly provided by:

Primary Rails Voltage Regulation

The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range.







5VSB Regulation

The following chart shows how the 5VSB rail deals with the loads we throw at it.


Hold-up Time

Hold-up time is a very important PSU characteristic and represents the amount of time, usually measured in milliseconds, a PSU can maintain output regulations as defined by the ATX spec without input power. In other words, it is the amount of time the system can continue to run without shutting down or rebooting during a power interruption. The ATX specification sets the minimum hold-up time to 16 ms with the maximum continuous output load. In the following screenshot, the blue line is the mains signal and the yellow line is the "Power Good" signal. The latter is de-asserted to a low state when any of the +12V, 5V, or 3.3V output voltages fall below the undervoltage threshold, or after the mains power has been removed for a sufficiently long time to guarantee that the PSU cannot operate anymore.



This unit's hold-up time was pretty long, so SilentiumPC did not cheap out on the bulk capacitor, using one that is large and expensive instead.

Inrush Current

Inrush current or switch-on surge refers to the maximum, instantaneous input-current drawn by an electrical device when first turned on. Because of the charging current of the APFC capacitor(s), PSUs produce large inrush-current right as they are turned on. Large inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays and bridge rectifiers; as a result, the lower the inrush current of a PSU right as it is turned on, the better.



A large hold-up time will most likely make a large bulk cap a necessity, which increases inrush current. The Supremo unit registered one of the highest inrush current readings for a unit of its capacity.

Voltage Regulation and Efficiency Measurements

The first set of tests revealed the stability of the voltage rails and the efficiency of the Supremo M1-700. The applied load was equal to (approximately) 20%, 40%, 50%, 60%, 80%, 100%, and 110% of the maximum load the PSU can handle.

We conducted two additional tests. In the first test, we stressed the two minor rails (5V and 3.3V) with a high load while the load at +12V was only 0.10 A. This test reveals whether the PSU is Haswell ready or not. In the second test, we dialed the maximum load the +12V rail could handle while the load on the minor rails was minimal.

Voltage Regulation & Efficiency Testing Data - SilentiumPC Supremo M1-700
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyFan SpeedFan NoiseTemp
(In/Out)
PF/AC
Volts
20% Load9.551A1.971A1.969A0.976A139.73W93.00%0 RPM0 dBA 47.83°C0.861
12.371V5.066V3.346V5.121V150.25W 37.50°C230.3V
40% Load19.507A3.950A3.959A1.175A279.71W93.76%660 RPM31.5 dBA 38.91°C0.914
12.332V5.052V3.332V5.105V298.32W 41.67°C230.2V
50% Load24.382A4.955A4.962A1.570A349.66W93.48%675 RPM32.9 dBA 40.96°C0.930
12.311V5.047V3.323V5.091V374.03W 44.51°C230.2V
60% Load29.269A5.950A5.968A1.968A419.64W92.78%900 RPM38.9 dBA 42.53°C0.939
12.296V5.036V3.316V5.076V452.28W 46.47°C230.2V
80% Load39.258A7.959A7.997A2.370A559.56W92.05%1170 RPM40.1 dBA 43.63°C0.949
12.258V5.021V3.300V5.055V607.90W 48.56°C230.1V
100% Load49.905A8.982A9.027A2.980A699.48W91.16%1315 RPM42.5 dBA 44.39°C0.954
12.219V5.010V3.290V5.030V767.35W 49.64°C230.0V
107% Load54.059A8.990A9.037A2.982A749.41W90.85%1315 RPM42.5 dBA 46.19°C0.956
12.204V5.006V3.285V5.026V824.90W 52.05°C229.9V
Crossload 10.098A14.015A14.005A0.003A118.36W87.32%0 RPM0 dBA 53.79°C0.848
12.373V5.041V3.319V5.125V135.55W 42.24°C230.3V
Crossload 257.958A1.002A1.003A1.002A721.06W91.66%1300 RPM42.1 dBA 41.98°C0.955
12.209V5.026V3.313V5.085V786.65W 43.21°C230.0V
The Supremo M1-700W shut down after a while once its operating temperature reached 45°C with the 110 % of its maximum-rated-capacity load (770 W), which forced us to dial in a lower load during our overload test. However, this isn't a big deal since our 110% load test operates the unit outside of its specifications and at very high ambient temperatures. OTP (Over Temperature Protection), not OPP (Over Power Protection), probably had to interfere to protect the unit, which is good since it shows that the protections are in place and working properly. We would, however, prefer OTP to have a higher threshold since this is a Platinum unit and its energy losses are low, which its crazily high efficiency readings in the above tests confirm. As you can see, efficiency peaked at an impressive 94% with 40 % load and was well over 87% during the CL1 test; these are very high numbers for even a Platinum unit. Take into account the Supremo's pretty large bulk cap that can cause significant energy losses and the overall efficiency looks even more impressive.