Ripple Measurements

In the following table you will find the ripple levels that we measured on the main rails of TTB800G. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V, 3.3V and 5VSB).

Ripple Measurements
Thortech TTB800G
Test12 V5 V3.3 V5VSBPass/Fail
20% Load7.4 mV6.8 mV6.0 mV3.0 mVPass
40% Load10.0 mV7.6 mV6.6 mV5.2 mVPass
50% Load12.6 mV8.0 mV6.8 mV6.8 mVPass
60% Load15.6 mV8.8 mV7.6 mV8.2 mVPass
80% Load24.8 mV10.8 mV9.0 mV10.0 mVPass
100% Load43.8 mV15.6 mV13.2 mV12.8 mVPass
Crossload 110.0 mV9.8 mV7.0 mV4.0 mVPass
Crossload 244.2 mV15.2 mV15.0 mV11.8 mVPass

Ripple/noise suppression overall is good, however we noticed a big increase of +12V ripple between 80% and 100% load. This shows that the 800W of the maximum stated capacity are close to the actual limits of this platform.

Ripple at Full Load

In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V and 5VSB). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. For all measurements we set 0.02 V/Div (each vertical division/box equals to 0.02V) as standard.



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Value & Conclusion