Ripple Measurements
In the following table you will find the ripple levels that we measured on the main rails of TTB800G. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V, 3.3V and 5VSB).
Ripple Measurements Thortech TTB800G |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
20% Load | 7.4 mV | 6.8 mV | 6.0 mV | 3.0 mV | Pass |
40% Load | 10.0 mV | 7.6 mV | 6.6 mV | 5.2 mV | Pass |
50% Load | 12.6 mV | 8.0 mV | 6.8 mV | 6.8 mV | Pass |
60% Load | 15.6 mV | 8.8 mV | 7.6 mV | 8.2 mV | Pass |
80% Load | 24.8 mV | 10.8 mV | 9.0 mV | 10.0 mV | Pass |
100% Load | 43.8 mV | 15.6 mV | 13.2 mV | 12.8 mV | Pass |
Crossload 1 | 10.0 mV | 9.8 mV | 7.0 mV | 4.0 mV | Pass |
Crossload 2 | 44.2 mV | 15.2 mV | 15.0 mV | 11.8 mV | Pass |
Ripple/noise suppression overall is good, however we noticed a big increase of +12V ripple between 80% and 100% load. This shows that the 800W of the maximum stated capacity are close to the actual limits of this platform.
Ripple at Full Load
In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V and 5VSB). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. For all measurements we set 0.02 V/Div (each vertical division/box equals to 0.02V) as standard.
Ripple at Crossload 1
Ripple at Crossload 2