Ripple Measurements
You will see the ripple levels we measured on the rails of the SF-750F14EG in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Super Flower SF-750F14EG |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 4.4 mV | 3.9 mV | 5.5 mV | 5.2 mV | Pass |
---|
20% Load | 6.0 mV | 4.2 mV | 5.4 mV | 4.9 mV | Pass |
---|
30% Load | 6.9 mV | 4.4 mV | 6.3 mV | 5.3 mV | Pass |
---|
40% Load | 7.5 mV | 5.1 mV | 6.7 mV | 5.3 mV | Pass |
---|
50% Load | 8.2 mV | 5.4 mV | 5.9 mV | 5.5 mV | Pass |
---|
60% Load | 9.3 mV | 5.7 mV | 6.1 mV | 5.8 mV | Pass |
---|
70% Load | 10.3 mV | 6.4 mV | 6.8 mV | 6.2 mV | Pass |
---|
80% Load | 10.8 mV | 6.6 mV | 6.3 mV | 7.3 mV | Pass |
---|
90% Load | 11.1 mV | 6.9 mV | 7.0 mV | 8.0 mV | Pass |
---|
100% Load | 11.6 mV | 7.6 mV | 7.0 mV | 8.7 mV | Pass |
---|
110% Load | 12.0 mV | 7.8 mV | 7.0 mV | 8.9 mV | Pass |
---|
Crossload 1 | 5.3 mV | 4.7 mV | 6.3 mV | 11.0 mV | Pass |
---|
Crossload 2 | 11.1 mV | 7.4 mV | 6.8 mV | 7.0 mV | Pass |
---|
Super Flower's platform delivers outstanding ripple-suppression results. We do believe that the caps on the modular cables could easily be left out. This platform offers incredibly clean outputs as is, which means several mV more wouldn't curtail its performance at all.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2