Ripple Measurements
You will see the ripple levels we measured on the rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Seasonic Snow Silent-750 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 12.0 mV | 10.6 mV | 13.5 mV | 5.9 mV | Pass |
---|
20% Load | 16.0 mV | 11.2 mV | 13.9 mV | 6.4 mV | Pass |
---|
30% Load | 18.9 mV | 11.6 mV | 13.9 mV | 6.6 mV | Pass |
---|
40% Load | 19.1 mV | 13.0 mV | 13.5 mV | 7.7 mV | Pass |
---|
50% Load | 20.9 mV | 12.1 mV | 14.2 mV | 8.2 mV | Pass |
---|
60% Load | 21.3 mV | 12.6 mV | 14.4 mV | 9.7 mV | Pass |
---|
70% Load | 22.6 mV | 12.9 mV | 14.9 mV | 10.3 mV | Pass |
---|
80% Load | 22.3 mV | 13.8 mV | 15.0 mV | 11.4 mV | Pass |
---|
90% Load | 23.5 mV | 13.5 mV | 15.7 mV | 12.8 mV | Pass |
---|
100% Load | 25.2 mV | 14.5 mV | 16.5 mV | 14.0 mV | Pass |
---|
110% Load | 27.8 mV | 15.8 mV | 17.9 mV | 15.5 mV | Pass |
---|
Crossload 1 | 17.0 mV | 14.1 mV | 16.2 mV | 28.0 mV | Pass |
---|
Crossload 2 | 25.4 mV | 12.7 mV | 14.6 mV | 14.0 mV | Pass |
---|
Ripple performance was perfect on all rails, proving yet again that Seasonic's designs are ripple-proof.
Ripple at Full Load
You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2