Ripple Measurements
You will see the ripple levels we measured on the HCP-850's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).
Ripple Measurements - Antec HCP-850 |
---|
Test | 12 V | 5 V | 3.3 V | 5VSB | Pass/Fail |
---|
10% Load | 5.9 mV | 8.1 mV | 9.2 mV | 6.5 mV | Pass |
---|
20% Load | 13.5 mV | 8.6 mV | 9.3 mV | 7.1 mV | Pass |
---|
30% Load | 15.0 mV | 9.3 mV | 10.0 mV | 6.8 mV | Pass |
---|
40% Load | 13.5 mV | 8.9 mV | 10.2 mV | 7.6 mV | Pass |
---|
50% Load | 14.3 mV | 8.8 mV | 10.4 mV | 7.4 mV | Pass |
---|
60% Load | 16.9 mV | 9.5 mV | 11.0 mV | 8.5 mV | Pass |
---|
70% Load | 18.9 mV | 9.3 mV | 11.9 mV | 8.6 mV | Pass |
---|
80% Load | 19.7 mV | 10.1 mV | 12.2 mV | 8.4 mV | Pass |
---|
90% Load | 21.7 mV | 10.7 mV | 12.7 mV | 8.1 mV | Pass |
---|
100% Load | 22.5 mV | 12.2 mV | 14.9 mV | 10.0 mV | Pass |
---|
110% Load | 22.7 mV | 11.1 mV | 14.8 mV | 9.8 mV | Pass |
---|
Crossload 1 | 23.3 mV | 11.2 mV | 14.8 mV | 5.5 mV | Pass |
---|
Crossload 2 | 22.2 mV | 17.0 mV | 16.0 mV | 8.3 mV | Pass |
---|
As expected, ripple suppression was superb! This unit will supply your system with incredibly clean voltages, which will prolong the life-cycle of such sensitive components as electrolytic caps.
Ripple at Full Load
You can see the main rails' AC ripple and noise (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.
Ripple at 110% Load
Ripple at Crossload 1
Ripple at Crossload 2