Antec High Current Pro Platinum 850 W Review 7

Antec High Current Pro Platinum 850 W Review

Performance Rating, Performance per Dollar, Noise & Efficiency Rating »

Ripple Measurements

You will see the ripple levels we measured on the HCP-850's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Antec HCP-850
Test12 V5 V3.3 V5VSBPass/Fail
10% Load5.9 mV8.1 mV9.2 mV6.5 mVPass
20% Load13.5 mV8.6 mV9.3 mV7.1 mVPass
30% Load15.0 mV9.3 mV10.0 mV6.8 mVPass
40% Load13.5 mV8.9 mV10.2 mV7.6 mVPass
50% Load14.3 mV8.8 mV10.4 mV7.4 mVPass
60% Load16.9 mV9.5 mV11.0 mV8.5 mVPass
70% Load18.9 mV9.3 mV11.9 mV8.6 mVPass
80% Load19.7 mV10.1 mV12.2 mV8.4 mVPass
90% Load21.7 mV10.7 mV12.7 mV8.1 mVPass
100% Load22.5 mV12.2 mV14.9 mV10.0 mVPass
110% Load22.7 mV11.1 mV14.8 mV9.8 mVPass
Crossload 123.3 mV11.2 mV14.8 mV5.5 mVPass
Crossload 222.2 mV17.0 mV16.0 mV8.3 mVPass
As expected, ripple suppression was superb! This unit will supply your system with incredibly clean voltages, which will prolong the life-cycle of such sensitive components as electrolytic caps.

Ripple at Full Load

You can see the main rails' AC ripple and noise (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating, Performance per Dollar, Noise & Efficiency Rating
View as single page
Nov 23rd, 2024 15:36 EST change timezone

New Forum Posts

Popular Reviews

Controversial News Posts